3) TECHNICAL DATA
Motor power supply
Consumption
Max. thrust
Operating jogging
Protection level
Operating temperature
Useful stroke
Noise
Lubrication
Weight
4) OPERATING LIMITS
The following tables show the permitted maximum weight and width figures of the gate leaves.
BILL 4024
Max gate leaf weight (kg)
Max gate leaf (m)
In case of wind effect the limits can be significantly reduced.
5) HOW TO INSTALL THE SYSTEM
1) Define the height of the system from ground (the most centred possible with respect to the main door and corresponding to a rugged crossbeam).
2) Weld the P plate, taking account of figures X and Y of Fig. 2/3.
3) Release the actuator, as shown in the instruction manual. When the gate is closing, temporarily lock the S* bracket by keeping the K measure as per
Fig. 2/3. In these conditions, the actuator must not be positioned entirely at end of stroke, but 10mm extra-stroke should be still available.
By manually opening the gate leaf, check that the actuator does not hit the leaf or the pillar.
4) Only after this check, carry out the final welding of the S bracket. The actuator should be perfectly flat.
Important: the respect of dimensions indicated in Fig. 3 ensures the optimal operation of the automatic system. These different dimensions may cause
malfunctions.
In any case, the manufacturer shall be held unharmed with respect to damages caused by the non-respect of the dimensions indicated.
If it is not possible to carry out welding, adjustable brackets, which can be mounted by using screws (art B.SR), are available as optional accessory.
Fix the actuator to the bracket by means of screws and nuts supplied. Use washers as shown in Fig. 4.
Note: The difference between measures X and Y shall be never exceed 40mm. Greater differences cause the unsmooth movement of the gate.
Dimensions M and X should be carefully checked to avert that the actuator hits the pillar (dim. M) or the leaf (dim. Z).
The total stroke of the actuator is around 520mm. The stroke, however, cannot be entirely used. An extra stroke of around 10 mm should be always
provided both in the closing and opening phases.
* In the BILL4024 geared motor, the difference in height of brackets P and S shall be nil. These brackets should be therefore fitted at the same height
(Fig. 1, ref. A}
6) WIRE CONNECTIONS
BILL4024 is supplied with a pre-cabled wire, around 80 cm long, to be connected to the junction box fitted to the pillar:
The cable includes 2 terminals (BLUE/BROWN)
Note:
The motor cable shall be replaced only by an authorised assistance centre.
IT IS MANDATORY to connect the system to ground by using the special GND terminal, as provided by regulations in force.
WARNING
The insurance policy, which covers any damages or injuries caused by manufacture faults, requires that the installation comply with regulations in force
and Benincà original accessories be used.
BILL4024
24Vdc
5 A
2000 N
Intensivo
IP54
-20°C / +50°C
400 mm
<70 dB
Permanent grease
5,2 kg
85
100
300
400
500
3,5
3,0
2,5
2,1
1,8
9