Important! The fitting must be installed, flushed and
tested after the valid norms!
The hot and cold supplies must be of equal pressures.
Assembly (see page 35)
Gloves should be worn during installation to prevent crush-
ing and cutting injuries.
Where the contractor mounts the product, he should ensure
that the entire area of the wall to which the mounting plate
is to be fitted, is flat (no projecting joints or tiles sticking out),
that the structure of the wall is suitable for the installation
of the product and has no weak points.
The enclosed screws and dowels are only suitable for
concrete. For another wall constructions the manufacturer's
indications of the dowel manufacturer have to be taken
into account.
In case of emergencies, the lower part of the pipe can be
shortened by means of a fine saw.
The filter insert (A) must be used to ensure the standard
flow rate and to protect the hand shower against incom-
ing dirt by pipework. Do you want a larger water flow
rate, then you must use the filter packing (B) instead of
the filter insert (A).
Incoming dirt leads to defects or/and can damage parts
of the hand shower; such caused faults voids all liability
and guarantee claims. (see page 38)
To adjust the hot water limiter on single lever mixers, please
see page 39.
No adjustment is necessary when using a continuous flow
water heater.
The arm of the shower head is intended only to hold the
shower head. Do not load it down with other objects!
Important! The non return valves must be checked
regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
The product may not be used as a holding handle. A
separate handle must be installed.
8
English

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G ½":
anti-pollution function
Hansgrohe showers can be used together with hydraulically
and thermically controlled continuous flow heaters if the flow
pressure is at least 0,15 MPa before the shower fitting.
Spare parts (see page 4)
Operation (see page 41)
The shower system may only be used for bathing, hygienic
and body cleansing purposes.
Children as well as adults with physical, mental and/or
sensoric impairments must not use this shower system without
proper supervision. Persons under the influence of alcohol
or drugs are prohibited from using this shower system.
Do not allow the streams of the shower touch sensitive body
parts (such as your eyes). An adequate distance must be
kept between the shower and you.
Cleaning (see page 42)
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
150 mm
cold right - hot left