All the electrical connections must be done by quali ed personnel in a reliable and secure
mode.
• RED WIRE: connect to the positive of services valve, inserting a fuse.
• BLACK WIRE: alarm ground, connect to a motorcycle ground.
•
PURPLE
WIRE
: connect to a positive ignition key. On this wire must always be present a
positive, both in the starting phase that with motor on.
• YELLOW WIRES: connect one wire to the direction indicators of left side and the other wire to
the direction indicators of the right side.
• WHITE/BROWN WIRE: programmable negative output. See programmable functions.
This output can be programmed in the following ways:
1) Factory setting (Negative during alarm), every time that will be generated an alarm condition,
on this wire will be present a negative signal for all the alarm cycle (30 seconds).
2) Customized
setting
there will be a negative signal on the wire allowing you to activate an additional module (optional).
The negative signal will expire disarming the alarm with the remote control.
• BLUE WIRE: negative programmable input. See programmable functions.
This input can be programmed in the following ways:
1) Factory setting (Input switch stand / saddle): with armed alarm, every opening of the protected
areas (stand / saddle) will generate an alarm condition.
2)Customized programming (Command anti-robbery), with disarmed alarm and with the
motorcycle O , every ground signal (provided with a button previously connected) will activate
N
the anti-robbery function signalled by a short ash of the direction indicators.
• GREEN, GREEN-BLACK, GREEN-YELLOW WIRES: connect only 2 wires to make the safety
lock of the motorcycle. It's necessary follow the more appropriate schematic connections
2B depending on the type of plant of the motorcycle.
NOTE: the engine lock is active when is present a positive signal on the Yellow wire (starting key).
• RED, BROWN WIRES: connected to a dedicated connector for the status LED of the alarm.
• WITHE-RED, BROWN WIRES: connected to a dedicated connector for the electronic socket.
WARNINGS FOR INSTALLATION
ELECTRICAL CONNECTIONS
(Output for module): arming the alarm by remote control, after 5 seconds,
1 Positive
2 Button stand/saddle
3 Electronic key
4 LED positive
5 Direction indicator
6 Direction indicator
7 Negative
8 Positive
9
Lock engine
10 Lock engine COM
11 Lock engine NA
12 Negative alarm command
ignition
key
NC
10
12V Red wire
Blue wire
White-Red wire
Red wire
Yellow wire
Yellow wire
Black wire
Purple wire
Green-Black wire
Green wire
Green-Yellow wire
White-Brown wire
2A