Maintenance
Cleansing and Care
• To guarantee adequate cooling of the motor always keep
the ventilation slots clean and free of obstructions.
• Clean all residues or dirt from the container and hose
before storing the vacuum cleaner.
• Double-check any damage in the hose, accessories and
power cord.
Cartridge filter cleansing :
• Remove the cartridge filter as indicated in page 8.
• Clean the filter tapping carefully or using a brush to
remove residues. This type of cleansing shall not be made
indoors or in the living areas. Installing a new filter is
recommended to gain the best performance.
• Set a clean or new filter in place as indicated in page 8.
• Wet filters shall be removed from the container. Let dry
24 hours before installing in the filter cage.
Foam filter cleansing:
• Remove the foam filter as indicated in page 8.
• Use a soft soap and water solution to clean the filter.
Rinse with clean water.
• Put the filter outdoors to dry completely before installing
and using it again.
Troubleshooting
Problem
Cause
The vacuum cleaner is
• There is no power.
not working.
• Defective power cord.
• The container is full.
Dust is coming out
through the motor
• The cartridge filter is not set
cover.
or is damaged.
Reduction of efficiency
• There is blockage in the
and motor vibration /
nozzle, hose or container inlet.
speed.
• The cartridge filter is clogged
with fine dust.
Service
• The tool should only be serviced in a
Authorized Service Center. Service and maintenance made
by not qualified people may be dangerous and could
cause severe personal injury. It also makes the product
Warranty void.
Carbon brush replacement
• Checked periodically the carbon brushes when worn.
Replace only at a
Center.
• After replacing the carbons ask the technician to
double-check the new carbon brushes can move freely in
the carbon housing. Ask to have the tool turned on and
keep it running 5 minutes to make even the contact of
carbons and commuter.
• Use only original
brushes, designed specifically with the right strength and
electric resistance for each type of motor. Carbon brushes
with different specifications may damage the motor.
• When replacing carbon brushes both carbons should be
replaced simultaneously.
Solution
• Check the power supply, cables, circuit switches, and fuses.
• Unplug and check the power cord. If damaged repair in a
Authorized Service Center.
• Empty the container.
• Set or replace the cartridge filter.
• Inspect for blockages in the nozzle, hose and container entry.
• Remove the filter and clean or replace.
Authorized Service
spare carbon
9
ENGLISH