XC32 Connector: Main and Auxiliary Incremental Encoder
Table 2: Description of XC32 connector
XC32
1
A1
A1
2
3
B1
B1
4
5
Z1
Z1
6
7
NC
8
+5/12 V
9
EGND
10
A2
A2
11
12
B2
B2
13
14
Z2
Z2
15
16
NC
17
+5/12 V
18
EGND
In the applications that need higher speed accuracy or in positioning applications,
motor shaft speed feedback with an incremental encoder is necessary.
The connection to the inverter is done through the terminals XC32:1 to XC32:9,
according to the table 2. This input presents encoder fault detection.
The auxiliary encoder connection is done through the terminals XC32:10 to
XC32:18, according to the table 2.
This input can be used in applications that need an external encoder to perform
positioning or following blocks.
However, it cannot be used for the motor speed feedback, which is done by the
main encoder. This input does not present encoder fault detection.
6
Function
Main Encoder Signals
Not connected
Power supply for the encoder 5 or 12 V,
according to the S4:2
0 V reference power supply for the encoder
Auxiliary Encoder Signals
Not connected
Power supply for the encoder 5 or 12 V,
according to the S4:2
0 V reference power supply for the encoder
Specifications
Directional inputs:
Common mode for maximum voltage:
7 V
-
Maximum current: 500 mA
Directional inputs:
Common mode for maximum voltage:
7 V
-
Maximum current: 500 mA