Parameter name
Compressor
Compressor minimum ON time
Compressor minimum OFF time
Compressor OFF delay at door open
Zero crossing selection
Others
Delay of outputs at startup
DI1 configuration
oFF=not used, Sdc=status display output,
doo=door alarm with resumption,
doA=door alarm without resumption,
SCH = main switch, nig=day/ night mode,
rFd=reference displacement,
EAL=external alarm, dEF=defrost,
Pud=pull-down, Sc=condenser sensor
Serial address
Password
Sensor type selection
n5=NTC 5 K, n10=NTC 10 K,
Ptc=PTC, Pt1=Pt1000
Cooling/Heating
rE=refrigeration (cooling) Ht=heating
Display Resolution
0.1=steps of 0.1 °C, 0.5=steps of 0.5 °C,
1.0=steps of 1.0 °C
Relay 1 counter
(1 count=100 cycles of operation)
Predefined applications
Save settings as factory
WARNING: the earlier factory settings are
overwritten
Display at defrost
Air=actual air temperature,
FrE=freezed temperature, -d-="-d-" is displayed
DKRCC.EI.RL0.F2.ML/520H9653
Code
Min
Max
Unit
c--
C01
0
30
min
C02
0
30
min
C04
0
15
min
C70
no
yES
o--
o01
0
600
min
o02
oFF
Sc
o03
0
247
o05
no
999
o06
n5
Pt1
o07
rE
Ht
o15
0.1
1.0
o23
0
999
o61
AP0
AP5
o67
no
yES
o91
Air
-d-
Instruction sheet | ERC 211
App. 0
App. 1
App. 2
App. 3
(Def.)
0
0
0
2
2
2
0
0
0
yES
yES
yES
5
5
5
oFF
oFF
oFF
0
0
0
no
no
no
n10
n10
n10
rE
rE
rE
0.1
0.1
0.1
0
0
0
AP0
AP1
AP2
no
no
no
-d-
-
-d-
App. 4
App. 5
0
0
0.0
2
2
2.0
0
0
1
yES
yES
yES
5
5
5
oFF
oFF
oFF
0
0
-
no
no
no
n10
n10
-
rE
Ht
0(rE)
0.1
0.1
0.1
0
0
-
AP3
AP4
-
no
no
-
-d-
-
-d-
| 17