Bode Plot Module - Velleman PCSU200 Instrucciones Breves

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

T
B
HE
ODE PLOTTER MODULE
What ? :
Due to the unique scope and generator combination, an automated Bode plot function is possible.
This results in a powerful tool for amplifi er or fi lter measurements.
4
How ? :
Enable the Circuit Analyser window (
Connect the scope CH1 input to the output of the circuit or unit under test.
Connect the generator output to the input of the circuit or unit.
Adjust the generator output (
Adjust the setting of the Bode plot module like Volt range (
frequency start and stop range (4)...
Press 'Start' (
5) and observe the screen and measurement window (6)
If the signal is out of the screen range, adjust the Voltage range or generator output level.
1
5
3
6
1)
2) to a suitable level.
:
2
3) Volt scale,
11