IMPORTANT: Review and under-
stand the warnings in the Safety
section, page 2. They are needed
to safely operate this heater.
Follow all local ordinances and
codes when using this heater.
TO START HEATER
1. Follow all ventilation and safety information.
2. Locate heater to provide maximum circu-
lation of the heated air. Follow all location
requirements noted in Safety, pages
2 and 3.
3. Fill fuel tank with fuel and attach fuel cap.
Use only kerosene, #1/#2 diesel/fuel oil,
JET A or JP-8 fuels to avoid risk of fire or
explosion. Never use gasoline, oil drained
from crankcases, naphtha, paint thinners,
alcohol or other flammable fuels.
4. Plug heater's power cord into approved,
grounded, three-wire extension cord.
Extension cord must be at least 6 feet
(1.8 m) long.
Extension Cord Size Requirement
• 6 to 10 feet (1.8 to 3 m) long, use 18
AWG (0.75 mm
• 11 to 100 feet (3.3 to 30.5 m) long, use
16 AWG (1.0 mm
• 101 to 200 feet (30.8 to 61 m) long, use
14 AWG (1.5 mm
5. Plug extension cord into standard 120
volt/60 hertz, 3-prong grounded outlet.
6. Push ON/STOP button to ON. An alarm will
sound and the display will start countdown
to ignition. The heater will start and pump
pressure will be displayed for 6 seconds.
7. Push MODE/RESET button to select
desired operating mode.
Note: When operating in Thermostat
Mode, press the MODE/RESET button
once to change to Manual Mode. When
operating in Manual Mode, Press the
MODE/RESET button twice within 5 sec-
onds to change to Thermostat Mode.
Manual Mode LED On: Adjust output to
desired setting. Press
output. Press
Note: After startup, heater BTU output can
be immediately adjusted, but adjustments
will not take effect for 2 minutes. This al-
lows the heater to stabilize.
160108-01C
OPERATION
) rated cord
2
) rated cord
2
) rated cord
2
to raise the BTU
to lower the BTU output.
www.usaprocom.com
Thermostat Mode LED On: Adjust ther-
mostat by pressing
higher. Press
If thermostat set temperature is higher
than the surrounding air temperature by
3° F, the heater will ignite. If the thermostat
set temperature is lower than surrounding
air temperature, the heater will not ignite.
Heater output will adjust automatically to
maintain set temperature.
WARNING: This heater is
equipped with a thermostat.
Heater may start at any time.
TO STOP HEATER
1. Push ON/STOP button to stop heater.
2. Unplug heater when not in use.
TO RESET HEATER
1. Wait two minutes before restarting.
2. Push MODE/RESET button to restart
heater.
MANUAL MODE
MODE MANUEL/MODO MANUAL
THERMOSTAT MODE
MODE THERMOSTAT
THERMOSTATO MODO
MODE/RESET
MODO/RESTABLECER
`
MODE/REINITIALISATION
PUMP PRESSURE
PRESSION DE LA POMPE
PRESION DE BOMBA
`
STAND BY
ON/STOP
ENCENDER/APAGAR
MARCHE/ARRET
^
LED display will show surrounding temperature
unless up and down arrow keys are pressed.
After pressing these keys, display shows set
point temperature for five seconds and then will
change back to display surrounding temperature.
Exposure to direct sunlight or extreme cold may
affect temperature reading and/or thermostat
operation.
This thermostat will store the last set point
even if power is removed. Unit will maintain
this set point until a new set point is entered.
Figure 5 - Controls Display
FAULT CODES
This heater will display fault codes whenever
there is a control shutdown. See Trouble-
shooting, pages 9 - 12, before attempting to
rectify any problems with your heater.
to change set point
to change set point lower.
TEMPERATURE
TEMPERATURA
ADJUST
AJUSTE
ASSEMBLED IN THE USA BY:
`
ASSEMBLE AUX ETATS-UNIS PAR:
ENSAMBLADA EN LOS EE.UU.POR:
PROCOM HEATING, INC.
2800 GRIFFIN DRIVE
BOWLING GREEN, KY 42101
160167-02