Output Rating
Fuel (all models)
Fuel Tank Capacity
Fuel Consumption (per hr) 0.82 gal/3.1 L 1.19 gal/4.5 L
Pump Pressure
Electric Requirements
Amperage (Normal Run)
Typical Motor Speed
Motor
Shipping Weight
Heater Weight without
Fuel (approx)
WARNING: Use only kero-
sene, #1/#2 diesel/fuel oil, JET
A or JP-8 fuels to avoid risk
of fire or explosion. Never use
gasoline, oil drained from crank-
cases, naphtha, paint thinners,
alcohol or other highly flam-
mable fuels.
Use only kerosene, #1/#2 diesel*/fuel oil,
JET A, JP-8 fuels. Heavier fuels such as No.
2 fuel oil, No. 2 diesel fuel may also be used
but will result in:
WARNING: Provide a fresh air
opening of at least three square
feet (2,800 square cm) for each
100,000 BTU/HR rating. Provide
extra fresh air if more heaters
are being used. The minimum
ventilation requirements must
be followed to avoid risks as-
sociated with carbon monoxide
poisoning. Make certain these
requirements are met prior to
operating heater.
6

SPECIFICATIONS

PCK110VT
PCK160VT
80K-110K
110K-160K
Use only kerosene, #1/#2 diesel*/fuel oil, JET A or JP-8 fuels
5.5 gal/20.8 L
10 gal/37.9 L
6.9 PSI (hot)
6.7 PSI (hot)
120 V/60 HZ
120 V/60 HZ
2.9
3400 RPM
3400 RPM
1/4 hp
42 lbs/19 kg
71 lbs/32.2 kg
36 lbs/16.3 kg 60.5 lbs/27.4 kg 60.5 lbs/27.4 kg 66 lbs/29.9 kg

FUELS

VENTILATION

www.usaprocom.com
PCK175VT
125K-175K
10 gal/37.9 L
1.3 gal/4.9 L
6.8 PSI (hot)
120 V/60 HZ
3.2
3400 RPM
1/4 hp
1/4 hp
71 lbs/32.2 kg
• noticeable odor
• additional fuel filter maintenance
* Use of #2 diesel/fuel oil in extreme cold
temperatures may require nontoxic anti-icer
additives.
Do not use fuels heavier than No. 2 grade
or heavy oils such as oil drained from crank-
cases. These heavy oils will not ignite properly
and will contaminate the heater.
IMPORTANT: Use a KEROSENE ONLY (blue)
or DIESEL ONLY (yellow) storage container.
Be sure storage container is clean. Foreign
matter such as rust, dirt or water will cause the
ignition control assembly to shut down heater.
Foreign matter may also require heater's fuel
system to be frequently cleaned.
Example: A 220,000 Btu/Hr (64.5 kw) heater
requires one of the following:
• a two-car garage door [16 feet (4.88 meter)
opening] raised 5" (12.7 cm)
• a single-car garage door [9 feet (2.74 me-
ter) opening] raised 9" (22.9 cm)
• two, 30" (76.2 cm) windows raised 16"
(40.6 cm)
PCK220VT
160K-220K
14 gal/53 L
1.64 gal/6.2 L
8.4 PSI (hot)
120 V/60 HZ
3.4
4.6
3400 RPM
1/4 hp
77 lbs/35 kg
160108-01C
Tabla de contenido
loading

Este manual también es adecuado para:

Pck160vtPck175vtPck220vt

Tabla de contenido