ART. 337
Duty Cycle (X)
Cutting current (I2)
Output voltage (U2)
Rated no-load voltage (Uo)
IEC 60974-1 *
Rated supply voltage (U1)
Maximum current consumption (I1max)
Maximum effective current consumption
(I1eff max)
Cutting current (I2)
Output voltage (U2)
CEBORA
Maximum effective current consumption
CP162C
(I1eff max)
**
Degree of housing protection
* Machine data measured in accordance with standard IEC60974-1
** Machine data measured under actual cutting conditions with torch CP162C
NOTE:
After consulting the above table, size the power source electrical supply panel as appropriate. If using a three-phase
400 V electrical panel with 32 A sockets, reduce the cutting current to 120 A.
24
50%
60%
100%
130 A
125 A
105 A
132 V
130 V
122 V
345 V ÷ 382 V
3 ~ 50/60 Hz
208 V
220 V
230 V
57 A
53 A
51 A
42 A
40 A
38 A
130 A
160 V
50 A
IP23S
80%
100%
130 A
125 A
132 V
130 V
334 V ÷ 365 V
400 V
440 V
29 A
26 A
26 A
23 A
34 A