Model IVO Compact
Article no.
DC
Charge voltage absorption (25°C)
Charge voltage float (Wet; 25°C)
Charge voltage float (Gel; 25°C)
Total charge current
DC consumption with connected battery
Number of main outlets
Number of slave outlets (3A)
Charge characteristics
Max. absorption time, reduced output
Temperature compensation
Voltage compensation
Recommended DC fuse (Main)
Recommended DC fuse (Slave)
Wire size < 1.5m
Wire size > 1.5m
Recommended battery capacity
AC
Nominal Input voltage
Allowed input voltage range
Frequency
Full load consumption (230VAC)
AC cable
Power factor / cos phi
General
Specified operation temperature
Allowed operating temperature
None operating temperature
Operating humidity
Efficiency
Cooling
Protections
Short circuiting
Over heating
Protection degree
Options
Communication
Suitable as power supply without battery
Mechanical
Connections input/output
Dimensions (HxWxD)
Mounting holes
Weight
Cabinet
Directives:
Set points software
Max. bulk/abs time
Return amps
Abs voltage
Float voltage
Forced to float
SPECIFICATIONS IVO COMPACT
12/25-3 (230V)
43012500
14.25VDC
13.25VDC
13.80VDC
25A
<10mA
2
1
IUoUo / 3 stage / automatic / DIN 41772
6 hours (adjustable)
30mV/°C
Auto sense
30A-T
5A-T
6 mm²/AWG9
10mm²/AWG7
50~450Ah
180~250VAC
90~250VAC
50/60Hz
419VA (@230VAC)
3x0.75 mm²
0.99
0...+60 °C, derating above +40°C, 5% per °C
-20...+60 °C (may not meet all specified tolerances)
-25°...+85 °C (storage temperature)
95% max., non-condensing
90% (at nominal input voltage)
Variofan 'low noise'
Yes
Limited power by temperature sense circuit
IP21
Quasi RS232, modular RJ12 connection, to alter set points and to change
characteristics (optional interface required) or to connect a temperature
sensor and/or remote panel.
Yes, in the Forced to float mode.
Screw terminals, maximum wire size 16mm² / AWG 5
228 x 153 x 82 mm; 8.9 x 6.1 x 3.2 inch
Diameter 5mm
2.4 kg / 3.9 lbs
Anodized aluminium, strapton ABS blend, blue RAL 5021
- Generic emission and disturbances standard: EN 55014-1:1993
- Generic harmonic current emissions: EN61000-3-3:1995
- Generic & safety accreditations immunity standard: EN55014-2: 1997
- Electrostatic discharge : EN61000-4-2:1995
- Electrical fast transients: EN61000-4-4:1995
- Surge transient: EN61000-4-5:1995
- Conducted radio frequency disturbances: EN61000-4-6:1996
- Voltage dips: EN61000-4-11:1994
Default setting
360min.
2/16 of I-max
14.25/28.50VDC
13.25/26.50VDC
13.25/26.50VDC
24/10-2 (230V)
43021000
28.50VDC
26.50VDC
27.60VDC
10A
<5mA
1
1
6 hours (adjustable)
60mV/°C
Auto sense
20A-T
5A-T
4mm²/AWG11
6mm²/AWG9
50~300Ah
180~250VAC
90~250VAC
50/60Hz
336VA (@230VAC)
3x0.75 mm²
0.99
Set points software
Gel voltage setting
Diode compensation setting
DC alarm voltage
DC alarm delay
12/20-3 (120V)
43212500
14.25VDC
13.25VDC
13.80VDC
20A
<10mA
2
1
6 hours (adjustable)
30mV/°C
Auto sense
25A-T
5A-T
6 mm²/AWG9
10mm²/AWG7
50~450Ah
90~140VAC
90~250VAC
50/60Hz
334VA (@120VAC)
3x0.75 mm²
0.99
Default setting
550mV
600mV
12.50/25.00VDC
30s