FIAP Pond Active
back, push the closing hook inwards, and open the clamping ring. Remove the lid including the foam
filter package, turn upside down and place on a clean surface ensuring that the foam filters including
the filter disk are facing up. The foam filters could collapse as a result of mechanical stress and normal
ageing. Replace the foam filters if they rest on the bottom filter disk without gaps and when the wear
mark of the top disk is full visible. Unscrew the top filter disk by removing the screws, pull off foam
filters and clean thoroughly in a bucket of pond water by vigorously compressing. Remove the bottom
filter disk, thoroughly spray clean container, lid with meshed tube, both filter disks and clamping ring.
Ensure that the meshed tube fits completely in the collar diameter. Place the cover sealing ring on the
upper container rim, press the lid including the foam filter package onto the container. Place the
clamping ring on the container and cover rim (do not pinch the power cable!), press on the cover, allow
the closure to engage, push in the safety latch. Reconnect the hoses, start up the pump first, then
connect the power supply of the unit.
Cleaning the quartz glass tube
Adhere to the safety information given above! Disconnect the power supply, switch off the pump and
secure against unintentional switching on again. Undo the four screws of the UVC unit and carefully
pull out of the filter cover, clean the quartz glass using a moist cloth, pull out the flat sealing ring and
the protection tube and clean with water.
Replacing the UVC lamp
Change the UVC lamp after approx. 8,000 operating hours. Adhere to the safety information given
above! Disconnect the power supply, switch off the pump and secure against unintentional switching
on again. Undo the four screws of the UVC unit and carefully lift the unit out of the filter cover, unscrew
the clamping screw by turning counter-clockwise, then remove the quartz glass tube including the O
ring. Pull out and replace the UVC lamp.
Important! Only use lamps the designation and rating of which match the information on the
type plate.
Remove the O ring from the quartz glass and clean, clean the quartz glass tube using a moist cloth,
pull out the flat sealing ring and the protection tube, clean with water. Check components for damage
and replace, if necessary. Reassemble in the reverse order. Start up the pump first, then connect the
unit power supply. The UVC lamp only lights up after the complete re-assembly of the unit.
Storage/Over-wintering
Put the unit out of operation at water temperatures below 8 °C or, at the latest, when freezing
temperatures are to be expected. Drain and thoroughly clean the unit, check for damage. Remove,
clean, dry and store all foam inserts in a frost free environment. Ensure that the storage place is
inaccessible to children. Cover the filter container such that the ingress of rain water is excluded. Drain
all hoses, pipes and connections as far as possible.
Wearing parts
The UVC lamp, the quartz glass and the foam filters are wear parts and are excluded from the
warranty.
Disposal
Dispose of the unit in accordance with the national legal regulations. The UVC lamp needs special
disposal. Ask your specialist dealer.
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
9
www.fiap.com
FIAP Pond Active
Malfunctions
Trouble shooting
Cause
Water does not clear
- Unit has been in operation only
for a short time
- Inadequate pump capacity
- Water extremely soiled
- Excessive fish and animal
population
- Foam filters soiled
- Quartz glass tube soiled
No water coming from
- Pump power supply not
the outlet
connected
- Outlet blocked
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
Remedy
- The complete biological cleaning
effect is only achieved after several
weeks
- Readjust the pump capacity
- Remove algae and leaves from the
pond, perform a partial water change
- Guide value: approx. 60 cm fish
length per 1 m³ pond water
- Clean foam filters
- Remove UVC and clean quartz glass
tube
- Connect pump power supply
- Clean outlet
10
www.fiap.com