18 Specifications
Fault
LEDs on the
battery
3 LEDs emit
red light.
4 LEDs
flash red.
The blower swit‐
3 LEDs emit
ches off while in
red light.
operation.
The blower ope‐
rating time is too
short.
18 Specifications
18.1
STIHL BGA 86 Blower
Approved batteries:
– STIHL AP
– STIHL AR
– Blowing force: 15 N
– Maximum air speed: 69 m/s
– Average air speed: 58 m/s
– Air flow: 780 m³/h
– Weight without battery: 2.8 kg
For battery life see www.stihl.com/battery-life.
18.2
STIHL AP battery
– Battery Technology: Lithium-ion
– Voltage: 36 V
– Capacity in Ah: see rating label
– Energy content in Wh: see rating label
– Weight in kg: see rating label
– Permissible temperature range for operation
and storage: -10°C to +50°C
18.3
Noise and Vibration Data
K-value (uncertainty) for sound pressure levels is
2 dB(A). K-value (uncertainty) for sound power
0458-824-9821-B
Cause
The blower is too
warm.
There is a fault in the
battery.
There is a break in the
electrical connection
between the blower
and the battery.
The blower or the bat‐
tery is damp.
The blower is too
warm.
There is an electrical
fault.
The battery is not fully
charged.
The battery life has
been exceeded.
levels is 2 dB(A). K-value (uncertainty) for vibra‐
tion levels is 2 m/s².
STIHL recommends that you wear hearing pro‐
tection.
– Sound pressure level L
to EN 50636‑2‑100: 79 dB(A)
– Sound power level L
EN 50636-2-100: 90 dB(A)
– Vibration level a
EN 50636-2-100, control handle: 0.5 m/s²
The vibration values quoted above have been
measured according to a standardized test pro‐
cedure and may be used to compare electric
power tools. Depending on the type of usage,
the vibrations that actually occur may differ from
the values quoted. The vibration values quoted
may be used for an initial assessment of the
user's exposure to vibrations. The actual expo‐
sure to vibrations has to be estimated. This proc‐
ess may also take into account times during
which the electric power tool is switched off and
times during which it is switched on but running
off load.
Remedy
► Switch on blower.
► If 3 LEDs continue to flash red: Do not
use the blower and contact your STIHL
dealer for assistance.
► Remove the battery.
► Allow the blower to cool down.
► Remove battery and reinsert it.
► Switch on blower.
► If 4 LEDs continue to flash red: Do not
use the battery and contact your STIHL
dealer for assistance.
► Remove the battery.
► Clean electrical contacts in the battery
compartment.
► Insert battery.
► Allow blower or battery to dry.
► Remove the battery.
► Allow the blower to cool down.
► Remove battery and reinsert it.
► Switch on blower.
► Recharge the battery fully as described in
the User Manual for the STIHL AL 101,
300, 500 chargers.
► Replace battery.
pA
measured according to
wA
measured according to
hv
English
measured according
23