Xiaomi Mi Vacuum Cleaner Light Manual De Usuario página 9

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Specifications
Mi Vacuum Cleaner Light
Model
MJWXCQ03DY
Dust Compartment Capacity
Approx. 0.5 L
Net Weight
Approx. 2.3 kg
Input Current
0.5 A
Operating Power
220 W
Ba ery Service Life (excl. electric floor brush)
Electric Floor Brush
Model
Operating Power
15 W
Power Adapter
Model
BLJ15W260050P-VA
Input
100-240 V~ 50/60 Hz 0.5 A
Output
26.0 V
0.5 A 13.0 W
Manufactured By
Zhongshan Baolijin Electronic Co., Ltd.
All products bearing this symbol are waste electrical and electronic
equipment (WEEE as in directive 2012/19/EU) which should not be
mixed with unsorted household waste. Instead, you should protect
human health and the environment by handing over your waste
equipment to a designated collection point for the recycling of waste
electrical and electronic equipment, appointed by the government or local authorities.
Correct disposal and recycling will help prevent potential negative consequences to
the environment and human health. Please contact the installer or local authorities for
more information about the location as well as terms and conditions of such collection
points.
Item Dimensions
240 × 148 × 1132 mm
Ba ery Nominal Capacity
2500 mAh
Charging Time
Approx. 5 hours
Input Voltage
26.0 V
Noise Emission
≤ 79 dB
45 minutes on standard mode
13 minutes on turbo mode
MJWXCQ03DY-DS
Operating Voltage
21.6 V
Average Active Efficiency
84.6%
Efficiency at Low Load (10%)
71.43%
No-load Power Consumption
0.10 W
15
Precautions for Ba ery Use
The vacuum cleaner is in standby mode and cannot be used during charging.
The lithium-on ba ery pack contains substances that are hazardous to the
environment. Before disposing of the vacuum cleaner, please first remove the
ba ery pack, then discard, or recycle it in accordance with local laws and
regulations of the country or region it is used in.
Note: The vacuum cleaner must be turned off before removing the ba ery.
The ba ery should be disposed of in a safe manner.
How to Remove the Ba ery
1. Use a straight screwdriver to
remove the on/off bu on and the
bu on bracket, then use a tool to
pray open the vacuum cleaner cover.
Next, use a screwdriver to unscrew
the four screws. Then you can pull
the handle and motor cover to
separate the ba ery pack.
2. Remove the ba ery protective
cover, then release the four screws
on the cover with a screwdriver. Use
a scissor to cut off the tin plate
connecting the ba ery and PCB
board.
Ba ery Protective Cover
Screw
Screw
Tin Plate
Tin Plate
Vacuum Cleaner Cover
Bu on Bracket
Motor Cover
3. A er removing the up-bracket, the
ba ery pack can be taken out of from
the down-bracket. Then you can
dispose of the ba ery in accordance
with local laws and regulations.
16
Handle
Screw
Tabla de contenido
loading

Tabla de contenido