Note:
The control equipment may be destroyed even if it is incorrectly
2 x Wall bracket
connected only once. The warranty will be voided if the electrical
connection is not correct.
4 x Securing
screws (wood
Instructions for the electrician
screws) 5 x 35
DIN VDE 0100 and Accident Prevention Regulation BGV A2 must be
observed for connecting the stove and all electrical systems. An exter-
nal all-pole disconnecting device with full isolation according to overvol-
tage category III must be installed.
Screws 4 x
M5 x 12
Important:
Self-tapping
Mains connection leads must be flexible cables with polychlorophene
screws 3.9 x 9.5
sheaths. No connection leads are supplied with the stove. All the ables
Bottom panel
installed inside the cabin must be suitable for an ambient temperature
of at least 170°C. heat-resistant silicon cables must be used. The mini-
mum cross-section of the connection cable and the minimum size of
the sauna cabin are shown in the table (Table 1 page 8). Make the elec-
trical connection as shown in the connection diagram . A connection
diagram is additionally affixed to the inside of the duct cover. Fit the co-
ver after making the electrical connection. Please note that live cables
must not be routed visibly on the internal walls of the cabin for safety
reasons. In prefabricated sauna cabins the wall element with the air
Terminal box
supply opening generally has empty cable conduits or a duct for routing
the cable. If your cabin does not have any cable routing preparations,
we recommend that you install a connection socket (not supplied) to the
Foot
outside of the cabin. Drill a hole in the cabin wall near the cable infeed
from the stove and the connection socket. Thread the cable through the
hole to the external connection socket. All cables must be protected
Screws M5 x 12 4x
from damage. This can be achieved using installation ducting/piping or
using wooden covers.
Connection diagram
9 kW sauna stove with internal controller
Testing the insulation resistance
The resistance values between the various conductor terminals and
the housing (protective earth) can be measured using an insulation
resistance measuring unit. The total insulation resistance between the
conductor terminals and housing (protective earth) must definitely be
greater than 1 MOhm. Ohm values of the stove 33 – 39 Ω for 9 kW
sauna heater
7