5.2 Advanced programming

The module operating parameters are set in the advanced menu. Press
same time for 5 seconds to open this menu.
DATA
DESCRIPTION
Regeneration start mode:
0 - Regeneration start at the time set during the enabled
days.
1 - Regeneration start at the time set after the volume
treatment in the enabled days.
2 - Immediate start at the end of the volume treatment in the
enabled days.
5H00
:
3 - Start at intervals. Regeneration starts every 1-2-3-4-8-12
hours. Regeneration starts when the hour strikes, so if
regeneration is enabled every two hours, it will be carried
out at 0:00, 2:00, 4:00 and so on. NOTE: the first
regeneration is carried out at the time set in the basic
menu. This function is available during the enabled days.
Press
Prescale of the volumetric meter. Press
The parameter is composed of the integer part and of the
F 00
:
decimal part, separated by the decimal point.
This parameter is displayed after the start up mode only if a
volume start has been selected (SH-01 or SH-02).
Volume to be treated (expressed in litres) before starting the
regeneration. Press
hundreds are modified first, once they are properly set, press
to switch to the tenths and units setting. This parameter
2800
is displayed after the prescaler only if a volume start has
been selected (SH-01 or SH-02).
NOTE: See note 2 to calculate the volume of treatable water
between two subsequent regenerations.
Duration of the first regeneration cycle stop (minutes).
Press
1C00
:
stop will be skipped and the system will directly go to the
next stop.
or
to edit.
or
to edit. Thousands and
or
to edit. If the parameter is set to off, the
DEFAULT
0
14.0
or
to edit.
28000
5
29
and
at the
MIN - MAX
0-3
E
N
G
L
I
S
H
00 - 99.9
1000 - 9999
Of-99