Checking The Function; Remedy Of Faults; Maintenance And Cleaning - Oase Bitron Premium 60 W Instrucciones De Uso

Ocultar thumbs Ver también para Bitron Premium 60 W:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 77
5.2

Checking the function

 L
• The function display is lit when the UVC lamp is switched on.
• Bitron Premium 120 W / 180 W: The bright UVC light provides lighting for the function display. A
weakly lit function display indicates that the UVC clarifier is switched off. Recommended function
check:
– Only switch on one UVC clarifier at a time. Switch off adjacent UVC clarifiers.
6

Remedy of faults

Malfunction
The unit performance is not satisfactory
The UVC lamp is not lit
7

Maintenance and cleaning

W A R N I N G
Electrical current may cause death or severe injuries.
• Disconnect the power plug before carrying out any work on the unit.
• Secure the unit to prevent unintentional switching on.
C A U T I O N
The quartz glass and UVC lamp could break and result in cuts.
• Be careful when carrying out all work on the UVC clarifier in order to avoid cuts.
• Shocks, impacts and hectic movements should be avoided to prevent the breaking of glass.
N O T E
The unit may be damaged, if the water flow is suddenly interrupted downstream of the outlet
(e.g. by a slide valve). The sudden interruption can cause a temporary pressure increase of
over 1 bar (hydraulic shock).
• Switching off: First switch off the pump, then close the slide valve. If the unit is operated in
a filter system, first take the filter system out of operation.
• Switching on: First open the slide valve, then switch on the pump. If the unit is operated in a
filter system, start up the filter system last.
• As an alternative, install the slide valve upstream of the inlet.
Cause
The water is extremely soiled.
The quartz glass is soiled.
UVC lamp capacity is too low
Excessive pond volume
Flow rate too low or too high
Power plug is not plugged in
UVC lamp is defective
Connection is defective
UVC lamp has overheated
- EN -
Remedy
• Remove algae and leaves from the
pond.
• Clean the pond thoroughly.
• Change the water.
Clean the quartz glass.
The lamp must be replaced after 8000
operating hours.
Add additional UVC clarifier
Adhere to the recommended flow rate
Plug in the power plug
Replace the UVC lamp
Check the electrical connection
• The UVC lamp will automatically
switch on again once it has cooled
down
• If there is strong sunlight, position the
unit under a roof
• Increase the flow rate to prevent
increased heating in the water hous-
ing