10.5
Description of the inspection and servicing work
Proceed as follows to descale the heaters:
-
Remove the mains plug from the socket.
-
Turn the turbo steamer on its side.
-
Using an open ended spanner, open all blind plugs on the underside of the turbo steamer.
Remove limescale. Take care that the cross connections are also free.
-
-
Flush the housing with water.
-
Screw the blind plugs back in.
When tightening, take care that the blind plugs are securely fastened to avoid leakage.
Scan the QR code to get to the video tutorial how to descale a steam generator.
Translation of the original operating manual Steam Generator TD
14.11.2017
ATTENTION
Limescale can accumulate over time. This can lead to reduced steam production
performance and eventually to failure of the machine.
Blind plugs
You can find this video tutorial also on our website:
https://www.gg-technik.de/index.php/en/turbo-steamer
Choose your steam generator.
Maintenance
Site 45 of 96