Technical data
Type of machine:
Complete machine
Technical data:
Steam Generator TD9
Electrical power rating:
Electrical connection:
Electrical connector:
Mains cable:
Fusing:
Water connection:
Steam output connection:
Minimum water pressure:
Maximum steam pressure:
Amounts of steam:
Weight:
Length x width x height:
Steam Generator TD13
Electrical power rating:
Electrical connection:
Electrical connector:
Mains cable:
Fusing:
Water connection:
Steam output connection:
Minimum water pressure:
Maximum steam pressure:
Amounts of steam:
Weight:
Length x width x height:
Steam Generator TD16
Electrical power rating:
Electrical connection:
Electrical connector:
Mains cable:
Fusing:
Water connection:
Steam output connection:
Minimum water pressure:
Maximum steam pressure:
Amounts of steam:
Weight:
Length x width x height:
Translation of the original operating manual Steam Generator TD
14.11.2017
9.9 kW
3 phase / N / PE 400 V AC 50 Hz
male CEE 5 pole 16 A
approx. 5 m
16 A
GeKa coupling
NW 25
2.5 bar
2.5 bar
15 kg per hour
approx. 50 kg
760 mm x 345 mm x 690 mm
13,2 kW
3 phase / N / PE 400 V AC 50 Hz
male CEE 5 pole 32 A
approx. 5 m
20 A
GeKa coupling
NW 25
2.5 bar
2.5 bar
20 kg per hour
approx. 55 kg
760 mm x 345 mm x 690 mm
16,5 kW
3 phase / N / PE 400 V AC 50 Hz
male CEE 5 pole 32 A
approx. 5 m
25 A
GeKa coupling
NW 25
2.5 bar
2.5 bar
25 kg per hour
approx. 60 kg
760 mm x 345 mm x 690 mm
Technical data
Site 34 of 96
English