13. CONNECT WIRING (ALL BLOWERS)
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power from being switched on accidentally.
Position insert below the installed custom hood. Pull cable through hole in top of insert.
INTERIOR BLOWER: Remove the cable knock-out on the top of the rough-in plate. Remove
rough-in plate wiring cover. Place the wire clamp in the knock-out
hole, insert the cable through the wire clamp in the rough-in plate
wiring box. Tighten the wire clamp to secure the cable.
Connect cable into wiring box using provided wire connectors.
Connect wires as follow: BLACK to BLACK, WHITE to WHITE and
GREEN or bare wire under ground screw. DO NOT FORGET TO
CONNECT THE GROUND. Reinstall wiring cover.
IN-LINE OR EXTERIOR BLOWER: Remove rough-in plate wiring cover and connect wiring (see instructions included with in-line or
14. INSTALL THE ROUGH-IN PLATE (ALL BLOWERS)
INTERIOR BLOWER: Carefully install the rough-in plate inside the top of
the insert with 4 lock nuts. See picture at right.
IN-LINE OR EXTERIOR BLOWER: Refer to instructions included with ILB3, ILB6, ILB9, ILB11, EB6, EB9, EB12 or EB15 rough-in kit.
15. INSTALL THE TRANSITION (INTERIOR BLOWER)
Slide the transition over the adapter/damper. Seal the transition to the adapter/damper
using metal foil duct tape.
WARNING
!
exterior blower).
Secure the rough-in plate inside the top of the insert with 4 lock nuts.
HD0007
HD0042
HD0091
9
G
ROUND SCREW