Prime Source Grip Rite GR2540 Manual De Funcionamiento Y Lista De Piezas página 11

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

4. Install dipstick in crankcase, and tighten
securely before starting compressor. Make
sure black seal is in place between dipstick and
crankcase to prevent loss of oil during
compressor operation or movement.
5. Check power outlet circuit for correct capacity.
Compressor requires 120V, Single Phase, 14
Amps, 60 Hz. Fuses or circuit breakers must
be rated accordingly.
6. Use an extension cord with 3-prong grounding
plug. Extension cord must be sized to prevent
power loss and overheating of the motor:
Cord Length
Up to 25 ft.
Up to 100 ft.
Up to 150 ft.
Up to 250 ft.
7. Pull handle out until locking hole in handle is
aligned with locking pin on base of compressor.
Lock handle in extended position with locking
pin, and use handle to wheel compressor to
desired area of operation.
8. Position compressor on a secure, stable
surface, no more than 10 degrees off level.
9. Plug power cord in, and unscrew Air Tank Drain
at the bottom of the air tank. Start compressor
by moving On/Off lever up to the "ON" position.
Allow compressor to run for 10 minutes without
stopping. Watch for excessive vibration or
unusual noise while compressor motor is
running. If unit vibrates excessively or makes
unusual noise, shut compressor off by moving
On/Off lever to "OFF" position. Refer to
trouble-shooting chart for corrective action. If
no excessive vibration is noted, tighten the Air
Tank Drain, allow unit to fill the air tanks, and
proceed to step 10.
10. Check operation of Pressure Relief Valve by
pulling release ring out to exhaust air pressure
from tank. Release ring and allow pressure
relief valve to reseat. Contact your dealer if
Pressure Relief Valve does not operate
properly.
11. Compressor is now ready for regular operation.
Wire Gauge Size
12 ga.
10 ga.
8 ga.
6 ga.
10
Tabla de contenido
loading

Este manual también es adecuado para:

Grip rite gr2540lr

Tabla de contenido