WARNING:
Before being used for the first time, your new compressor requires a simple set-up procedure
that will help your unit deliver years of trouble-free service. Failure to follow all initial set-up
instructions may result in serious damage to your compressor, property damage, or serious
injury to operator and bystanders. Do not start compressor until all set-up steps have been
performed.
1. Remove compressor and wheel assemblies
from carton.
2. Install wheels on wheel mounts at bottom of
frame using hex head wheel bolts. Tighten
bolts securely with 1-1/4" wrench.
3. Unscrew shipping plug from crankcase. Add
non-detergent oil to compressor and check oil
level in sight glass or with dipstick. Oil level
must be between "L" (Low) and "H" (High)
marks on flat area of dipstick. Crankcase
capacity is ll.8 oz. (350 ml). Use chart below
for correct viscosity:
Air Temperature
14 – 40 F
40 – 80 F
Viscosity
SAE 20 (ISO 68)
SAE 30 (ISO 100)