SI T E P R E PA R AT I ON
Electrical Requirements
Installation must comply with all applicable electrical codes.
Locate the electrical supply within the shaded area shown
in the illustration below. A separate circuit servicing only
this appliance is required. A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
EL EC T R IC A L R EQ UI R EM ENT S
Electrical Supply
Service
Receptacle
CAUTION
The outlet must be checked by a qualified electrician
to be sure it is wired with the correct polarity. Verify the
outlet is properly grounded.
WARNING
Do not locate multiple portable socket-outlets, power
strip, or portable power supplies at the rear of the
appliance.
WARNING
Do not use an extension cord, two-prong adapter, or
remove the power cord ground prong.
7"
E
(178)
6"
(152)
75
1
/
"
2
(1918)
FROM FLOOR
RIGHT SIDE
OF OPENING
Electrical supply location
6 | Sub-Zero Customer Care 800.222.7820
115 VAC, 60 Hz
15 amp dedicated circuit
3-prong grounding-type
Plumbing Requirements
Installation must comply with all applicable plumbing codes.
Locate the water supply line within the shaded area shown
in the illustration below. Connect the water supply line to the
house supply with an easily accessible shut-off valve. Do
not use self-piercing valves. The water supply line must not
interfere with the installation of the anti-tip bracket.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
to the unit at all times. In this application, the water filtration
system must be bypassed by removing the filter. A copper
line is not recommended for this application.
P L U M B I N G R E Q U IR E M E N T S
Water Supply
Pressure
Excess Line for Connection
RIGHT SIDE
OF OPENING
3
6"
5
/
"
16
(152)
(132)
3"
(76)
AREA EXTENDS 1
/
"
2
(13)
FORWARD ON FLOOR
Water supply location
supplied
(2.4–8.3 bar)
1
/
" OD copper, braided
4
stainless steel, or PEX tubing
35–120 psi
(2.4–8.3 bar)
36"
(914)