SECTION 3
3.1
LINER INSTALLATION
STEP #1
•
Liners and contact tips are not supplied with guns and must be ordered and
installed separately. Follow the simple instructions below for proper installation
Ensure power source is off and torch is re-
moved from feeder before proceeding.
•
Remove insulator nozzle, tip and tip adaptor
and loosen liner set screw using 5/64" (2 mm)
Allen wrench supplied with the gun.
•
With torch straightened, grip conduit liner
with pliers and remove.
STEP #2
•
Feed liner into the euro connector and completely
through the unicable using short strokes to avoid
kinking. Twist liner clockwise if necessary.
•
Seat liner retainer with o-ring to shoulder inside liner
seat.
•
Secure by tightening liner set screw. Do not over-
tighten.
STEP #3
•
Trim conduit liner to 5/8" (16 mm) stick out.
•
Remove any burr that may obstruct wire feed, espe-
cially on flat wire type conduit liner.
Liners for MT-300GL, 400GL & 500GL
(10, 12 & 15 ft.) Hard Wires
.030 (0.8mm) ...................................................................... 37031
.035 (0.9mm) ...................................................................... 37032
.045-1/16 (1.2-1.6mm) .................................................... 37033
5/64-3/32 (2-2.4mm) ....................................................... 37034
7/64-1/8 (2.8-3.2mm) ....................................................952948
19