the wall reaches the minimum value indicated in the tank certification (part of the documentation provided with the unit).
• The life-span of the air tank depends mainly on the operating environment. Avoid installing the compressor in a dirty and corrosive environment as this can
greatly reduce the life-span of the tank.
G
• Do not anchor the tank or its components directly onto the ground or onto rigid structures. Assemble anti-vibration pads on the tank to prevent faults due to
excessive stress caused by vibration of the tank during use.
B
• Use the tank observing the temperature and pressure limits on the data plate and in the test report.
• Do not carry out welding, drilling or machining to modify the machine in any way.
MAINTENANCE
4
• BEFORE CARRYING OUT ANY MAINTENANCE, UNPLUG THE MACHINE, EMPTY THE ENTIRE TANK AND ALLOW THE MACHINE TO COOL DOWN
(FIG. 7, 8a, 8b, 8c).
• Check that all the screws, and those on the head of the unit in particular, are properly fastened (torque 10 Nm = 1.02 Kgm).
This check must be carried out before starting the compressor for the first time and after the first hour of operation.
OPERATION
Fastening of the head tie-rods
Cleaning the filter element
Replacing the small valve of the pressure switch (when applicable)
Replacing the filter element
Checking and cleaning the valve plate
Replacing the cylinder segment
Replacing the check valve
Replacing the valve plate
Replacing the filters of the dryer (when applicable)
Draining condensation in the tank
OPERATION
Fastening of the head tie-rods
Cleaning the filter element
Replacing the small valve of the pressure switch (when applicable)
Replacing the filter element
Checking and cleaning the valve plate
Replacing the cylinder segment
Replacing the check valve
Replacing the valve plate
Replacing the filters of the dryer (when applicable)
Draining condensation in the tank
• Loosen the small valve on the pressure switch (Fig. 9)
• Unscrew and remove the small valve (Fig. 10-11)
REPLACING THE SMALL VALVE OF THE PRESSURE SWITCH (WHEN APPLICABLE)
• Assemble the new small valve and fasten it in place.
CLEANING AND/OR REPLACING THE FILTER ELEMENT
• Undo the screws in the head using the Allen key (fig. 12)
• Remove the cylinder head (fig. 13)
• Check the filter element and replace it if necessary (fig. 14)
• Reassemble the head and tighten the screws (fig. 12)
CHECKING, CLEANING AND REPLACING THE VALVE PLATE
• Undo the screws in the head using the 5 mm Allen key (M6 socket screw) (fig. 12)
• Remove the cylinder head (fig. 13)
• Clean the valve plate and replace it if necessary (fig. 10)
• Reassemble the head and tighten the screws (fig. 12)
REPLACING THE CYLINDER SEGMENT AND GASKETS
• Undo the screws in the head using the Allen key (fig. 12)
• Remove the cylinder head and the valve plate (fig. 13)
• Replace the head gasket (fig. 14)
• Unfasten the cylinder with the same Allen key, removing the two screws connecting the cylinder to the guard (fig. 15)
TABLE 1 - MAINTENANCE SCHEDULE
NORMAL WORK ENVIRONMENT
EVERY 100 HOURS
This check must be carried out before starting the compressor for the first time and after the first hour
of operation.
Refer to the relative manual
24 h -----> 24 h -----> 24 h -----> ...
TABLE 2 - MAINTENANCE SCHEDULE
DAMP/DUSTY WORK ENVIRONMENT
EVERY 50 HOURS
This check must be carried out before starting the compressor for the first time and after the first hour
of operation.
Refer to the relative manual
24 h -----> 24 h -----> 24 h -----> ...
22
EVERY 1000 HOURS
EVERY 2000 HOURS
EVERY 500 HOURS