The Birch display does not use a nozzle or bolt. It is
the fountain unit running without any nozzle and al-
lows for the best fl ow rate and oxygen transfer!
Model
HP
8400EJF
2
3.1EJF
3
The Sequoia nozzle (marked S on the inside of the
cone) uses the 3/8" x 2.5" bolt.
3.1EJF ONLY
Model
HP
3.1EJF
3
Installation Instructions
STEP ONE
Use the ropes to position the Unit in the desired loca-
tion in the pond/lake (secure the cord near power
source to prevent it from being dragged into the wa-
ter). Anchor the ropes or secure them to the shoreline
so the ropes are free of slack, but not tight. To prevent
twisting of the unit due to torque, you should place
the anchor at least 3m from the fl oat for each meter of
depth (Ex. A 3m deep pond would require an anchor
9m horizontally from the fl oat.) For ease of removal,
you may choose to keep at least one anchor within
reach from shore, just below the water's surface.
8
Height
Width
3.5 m
1.8 m
3.0 m
4.0 m
Height
Width
4.6 m
3.0 m
Correct Anchoring
Incorrect Anchoring
STEP TWO (ALTERNATE INSTALLATION)
In ponds where the water level fl uctuates signifi cantly,
you may need to suspend a small weight (30cm of
2.54cm galvanize pipe works well) at the mid-point of
the rope to take up any slack as the water level drops.
The weight should be light enough so the Unit can rise
as the water level rises. This can also help hide ropes
by sinking them further below the surface.
Normal Water level
Anchor Rope
Secondary Weight
Low Water Level
High Water Level
STEP THREE
At this time the Fountain is ready for operation. It can
be plugged into the power supply at the pond edge.
ENJOY YOUR NEW KASCO EQUIPMENT!
Maintenance Recommendations
Under No Circumstances should anyone enter
the water while a fountain is operating. Turn Off and
Disconnect electrical power prior to any Maintenance
or Servicing
RCD (Residual Current Device) or GFCI are a safety
feature that can also alert you to electrical leaks in the
Kasco Power
Control Box
Power Cord