Astralpool GEL-MF 30 Manual De Uso E Instalación página 38

Equipo de producción de hielo
Ocultar thumbs Ver también para GEL-MF 30:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

- Drain
It is recommended a rigid plastic pipe with internal diameter of 18 mm and
constant flow of 3 cm per meter. The draining of remainder water it is made
by gravity; it is necessary a drianing with vertical air inlet near the connector
and that it go to the open siphon for a constant flow.
- Drain – Model cooled with water
The equipment cooled with water need a new line of drain separet with a
male connector 3/4" Gas that comes with the indication "Drain- Only for
cooled with water".
NOTE: All the water connections has to be perfect and realise according to
the local laws. In some cases it is necessary the intervention of a qualified
plumber.
OPERATION INSTRUCTIONS
STARTING
After a correct electrical, water and drain installation, follow the next
instructions for the starting up:
A. Open the tap and connect the plug or electric general switch located in the
electrical connexion line. The first GREEN LIGHT will light, showing the unit
is under tension.
NOTE: When the unit has been some time disconnected, the RED LIGHT
it is flashing during 3 minutes; afther these minutes it will start the motor ot
the gear reduction and after 5 seconds the compresor.
B. After the 3 minutes, the unit will start up activating the
following components:
- MOTOR / S REDUCTION GEAR COMPRESSOR
- MOTOR / S OF FAN(if the unit is cooling with air),
temperature sensor of the condenser located in the wings of the same.
C. After the compressor work 2 or 3 minutes, check that the ice go out
through the unloading hole and through the pipe go to the store.
NOTE. The first ice granule present a scarce consistence because the
temperature of evaporation still have to reach the normal functioning
value. Wait 10 minutes so as the evaporation temperature go down to
the normal functioning values so as the ice has the correct consistence.
NOTE. If after 10 minutes of being working the equipment the
temperature of the evaporator has not reach below 1°C due to an
inadequate quantity of cooler, the temperature sensor of the evaporator
detects this abnormal situation and consequently stop the unit. In this
circumstance, the YELLOW LIGHT switch on.
After 3 minutes, with the RED LIGHT flashing, the unit will start working.
D. Take out the front panel and if it is needed put the high and low pressure
gauge in their corresponding tyre valve to check the condensation and air
intake pressure.
controled by the
After diagnosing and eliminating the problem of this poor
evaporation temperature due to inadequate quantity of
cooler or excessive condensation temperature, press the
boton RESET located in the lid of the control
CHECKING THE PERFORMANCE WITH THE UNIT WORKING
5
Tabla de contenido
loading

Este manual también es adecuado para:

Gel-mf 30asGel-mf 30ws

Tabla de contenido