The SMART-SMOKE10 is a smoke detector for the detection of fire in the first phase. In case of smoke development, the SMART-SMOKE10
EN
will give a loud alarm tone of at least 85dB (A). The SMART-SMOKE10 can be connected and then the alarm will be reported in the TUYA
app and a scenario can be triggered. It is advised to test the smoke detectors every week using the test button on the smoke detectors. Keep this
manual in a safe place or in the meter cupboard.
RECOMMENDED MOUNTING PLACES FOR THE SMART-SMOKE10:
Place at least one smoke detector in the vicinity of the bedrooms. Make sure that an exit remains accessible or choose an escape route. Place the
detector where the escape route is, so that the smoke detector would go off before it would become inaccessible.
Make use of several detectors to increase safety in such a way that the escape route remains accessible.
Place at least one smoke detector on each floor of your home.
Place an Alarm at least in every bedroom where smoking is taking place or where there is equipment that could cause a fire.
Smoke, heat and combustion products will first pull up to the ceiling. After that, the smoke, heat and combustion products will continue horizontally.
If you mount the detector to the ceiling, keep a minimum distance of 50 cm from the wall and 61 cm from a corner. Smoke, heat and combustion
products will not get into a corner either.
DO NOT INSTALL IN THE FOLLOWING LOCATIONS:
The kitchen; Steam from cooking might give a false alarm.
The shower or bathroom; water damp might cause a false alarm and the moist environment might damage the detector.
The garage: The car exhaust might cause a false alarm.
In front of a fan or nearby the exhaust of an air conditioner or heater.
In a ceiling nook.
In rooms where the temperature could reach below -10°C or beyond 40°C.
Do not paint or otherwise cover this smoke detector.

INSTALLATION INFORMATION:

Attach the ceiling plate using the included plugs and screws to the ceiling on a location of choice. Wall mounting is not recommended for smoke
detection.
Insert the batteries into the detector.
1
The detector is now ready for use. Do not attach the detector on the ceiling plate until you have successfully connected the smoke detectors.
2
Do not place here
Place near here
Minimum distance