Filter Replacement And Care - MoistAir MA0601 Manual De Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Humidistat
The humidistat located on the power cord senses the percentage of humidity in the
air. It causes the humidifier to cycle on and off to maintain the selected humidity
SET point. The fan will turn on if the "ROOM" reading falls 3% below the SET
point and will continue to run the humidifier until a reading of 1% above the SET
point is achieved. The fan will turn off until the ROOM reading falls 3% below the
SET point again.
NOTE
: Be sure that the humidistat, which is located on the power cord, is free
from obstruction and away from any hot air source.
Control Lock Out
To avoid unwanted tampering with the humidifier settings the controls can be
locked.
Activation Procedure
After the humidifier functions have been set up, hold the power button down for 5
seconds. The display will show "CL" for 2 seconds; release the power button and
the control will resume the display of the room humidity. The room humidifier will
continue to function with the locked in settings. If buttons are operated while "CL"
is active, the "CL" is displayed and settings are unaffected.
Deactivation Procedure
To deactivate the "CL" function simply press and hold the power button for 5
seconds. "CL" will flash at the rate of 1 second on and 1 second off for a period of
2 seconds and then resume the display of room humidity.
CAUTION:
To help retard bacteria
growth and keep maximum
efficiency, the filter should be
replaced at least once per season,
or more often under hard water
conditions. Use MAF-2 replacement
filter.

Filter Replacement and Care

Replace the evaporative wicking filter at least once per humidification season or
more depending on water conditions in your area.
Filter Replacement
1. Unplug humidifier. Before removing the filter, move the humidifier to an area not
susceptible to water damage. (i.e. kitchen or bath areas).
2. Remove the water bottle and set aside. Be sure not to bump or damage the fill
valve.
3. The upper housing and the base are held together by two hooks at the front of
the housing and a flexible snap in the rear. To remove the housing, press in on the
triangular shaped snap at the rear of the humidifier, below the cord exit, while lifting
upward, tilting the upper housing forward to clear the hooks at the front of the base.
4. Set the upper housing aside. The filter is now accessible.
WARNING:
shock or injury from moving parts,
always unplug humidifier before
removing or replacing any parts.
9
To reduce the risk of
Tabla de contenido

Solución de problemas

loading

Tabla de contenido