Stray welding currents/voltages may destroy earth conductors, damage electrical equipment or cause components to warm up which
may cause a fire.
- All welding connections must be firmly secured, check regularly !
- Check that the metal piece fixation is strong and without any electrical problems !
- Attach or hang all the electrically conductive elements,such as the trolley in order to insulate them
- Do not place any electrical equipment such as drills on top of the welding machine without insulating them !
- Always place welding torches or electrodes holders on an insulated surface when they're not in use !
INSTALLATION
Rules to follow :
• The wire feeder must be switched on with all access panels closed.
• Put the wire feeder on a floor with a maximum incline of 10°.
• The machine must be placed in a sheltered area away from rain or direct sunlight.
• The equipment's protection level is IP23, which means :
- Protection against acess to dangerous parts from solid bodies of a ≥12.5mm diameter and,
- Protection against the rain inclined at 60° towards the vertical.
These devices can be used outside in accordance with the IP23 protection index.
The manufacturer does not incur any responsability regarding damages to both objects and persons that result from an incorrect
and/or dangerous use of the machine .
MAINTENANCE / RECOMMENDATIONS
• Maintenance should only be carried out by a qualified person. Annual maintenance is recommended.
• Ensure the wire feeder is disconnected from the welding machine, and wait for two minutes before carrying out maintenance
work.
• Remove the casing 2 or 3 times a year to remove any excess dust. Take this opportunity to have the electrical connections checked by a qualified
person, with an insulated tool.
• Regularly check the connection cable between the wire feeder and the machine. If damaged, the connection cable cable must be replaced.
• Warning ! If the welding machine is transported/handled by another solution than the one recommended by the manufacturer; the wire feeder
casing must be insulated from the transporting/handling solution.
Rules to follow :
• The wire feeder must be switched on with all access panels closed.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorized by the manufacturer should perform the installation of the welding equipment. During set up,
the operator must ensure that the machine is unplugged. It is recommended to use the welding cables supplied with the unit in
order to obtain the optimum product settings.
Risk of injury due to moving parts!
The wire feeders contain moving parts that may catch hand, hair, clothes or tools which can lead to injuries! Take extra care.
• Do not place your hand on mobile/pivoting/wire feeding parts of the machine!
• Make sure that all panels remain closed when in use !
HARDWARE DESCRIPTION (FIG-1)
1-
Lifting ring
2-
Connection cable access
3-
Reel support
4-
Wire feeding motor
5-
Rocker switch Wire inch / Gas purge
6-
Transport handles.
7-
Man to Machine Interface
8-
EURO connector
CONTROL BOARD (MMI) (FIG-2)
1-
Voltage display
2-
Wire speed / current display
3-
Amperes indicator
4-
m /mn indicator
5-
Overheat indicator
6-
Disruption of normal operations indicator
7-
Voltage adjustment knob:
16
8-
Wire speed / inductance adjustment knob
EXAFEED 4L
9-
Water connector
10-
Water connector
11-
Remote control cable connector
12-
Connection cable control connector
13-
Gas connector
14-
Power relay connector
15-
Water connector
16-
Water connector
11-
Inductance mode indicator
12-
Active remote control indicator
13-
Locked keypad indicator
14-
Locked keypad button
15-
Remote control selection button / remote control activation
16-
2T indicator
17-
4T indicator
18-
Spot/Delay indicator
EN
Tabla de contenido