Thermon Terminator ECM-R-WP Instrucciones De Instalación página 3

Terminator
1.
Slide appropriate IEK insulation entry
kit components onto cable.
3.
Mount expediter to bracket using
M5 x 8mm screws and M5 lock washers.
6.
Insert cable into expediter.
The Heat Tracing Specialists
TM
ECM-R-WP
2a.
Mounting Method 1: Secure wall mount
bracket to mounting surface using pipe
band provided with kits.
4.
Position RTD Sensor(s) in grommet. Do
not pull from the sensor end when routing
through the expediter assembly. Pull
sensor from the lead wire portion.
7.
Terminate cable with appropriate PETK
termination kit. Refer to PETK installation
instructions. Push excess cable back
through expediter. Tighten cap securely.
Tape cable expansion loop to pipe.
®
INSTALLATION PROCEDURES
2b.
RTD
Lead Wire
RTD
Sensor
5.
8.
3
Mounting Method 2: Secure wall mount
bracket to mounting surface using
customer supplied screws, fl at washers,
and nuts.
Cut end of cable at angle to aid in piercing
grommet. Leave additional cable for
expansion as needed.
Mount junction box base on expediter.
Make sure to align slots to properly
orient junction box base. Tighten nut
with Terminator-LN-Tool. If mounting
horizontally, threaded gland holes must
face downward.
loading