The device does not start up, the motor buzzes
Voltage drop due to a weak mains grid or when using an
extension cable
1. When switching on, first press the lever on the high-
pressure gun and then switch on the device "I/ON".
Device does not reach required pressure
The water supply is too low
1. Open the water tap fully.
2. Check the water inlet for an adequate flow rate.
The sieve in the water connection is dirty.
1. Pull the sieve in the water connection out using flat
pliers.
2. Clean the sieve under running water.
Air is in the device.
1. Vent the device:
a Switch on the device without a connected spray
lance for a maximum of 2 minutes.
b Press the high-pressure gun and wait until the
water escaping from the high-pressure gun is
free of air bubbles.
c Connect the spray lance.
d Observe the maximum suction height during suc-
tion operation (see chapter Technical data).
Strong pressure fluctuations
1. Clean the high-pressure nozzle:
a Use a needle to remove dirt from the nozzle drill.
b Rinse the high-pressure nozzle from the front
with water.
2. Check the water supply volume.
Device leaking
1. The device leaks a small amount for technical rea-
sons. If the leak is severe, request authorised Cus-
tomer Service.
Detergent is not sucked in
1. Use the Vario Power spray lance and turn it to "MIX".
2. Check that the Plug 'n' Clean detergent bottle is sit-
ting correctly with the opening facing down in the de-
tergent connection.
Warranty
The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)
Technical data
Electrical connection
Voltage
Phase
Frequency
Power rating
Degree of protection
Protection class
Power protection (slow-
blowing)
16
K 5 Premium
Power
Power
Control
Control
V
230
230
~
1
1
Hz
50
50
kW
2,1
2,1
IPX5
IPX5
I
I
A
10
10
Water connection
Feed pressure (max.)
Input temperature (max.)
Input amount (min.)
Suction height (max.)
Device performance data
Operating pressure
Max. permissible pressure MPa
Water flow rate
Maximum flow rate
Detergent flow rate
High-pressure gun recoil
force
Dimensions and weights
Typical operating weight
Length
Width
Height
Determined values in acc. with EN 60335-2-79
Hand-arm vibration value m/s
Uncertainty K
Sound pressure level L
Uncertainty K
pA
Sound power level L
uncertainty
WA
Subject to technical modifications.
EU Declaration of Conformity
We hereby declare that the machine described below
complies with the relevant basic safety and health re-
quirements in the EU Directives, both in its basic design
and construction as well as in the version placed in cir-
culation by us. This declaration is invalidated by any
changes made to the machine that are not approved by
us.
Product: High-pressure cleaner
Type: 1.324-xxx
Currently applicable EU Directives
2000/14/EC
2014/30/EU
2006/42/EC (+2009/127/EC)
2011/65/EU
Harmonised standards used
EN 50581
EN 55014-1: 2017
EN 55014-2: 2015
EN 60335-1
EN 60335-2-79
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN 62233: 2008
Conformity evaluation procedure used
2000/14/EC: Annex V
English
K 5 Premium
Power
Control
MPa
1,2
°C
40
l/min
10
m
0,5
MPa
12,5
14,5
l/min
7,5
l/min
8,3
l/min
0,3
N
20
kg
15,8
mm
414
mm
306
mm
588
2
<2,5
2
m/s
0,6
dB(A) 76
pA
dB(A) 3
+ K
dB(A) 92
WA
Power
Control
1,2
40
10
0,5
12,5
14,5
7,5
8,3
0,3
20
14,8
402
306
588
<2,5
0,6
76
3
92