ELECTRICAL REQUIREMENTS cont.

POWER SUPPLY CORD

Wiring Requirements
For model HWE15XCR, HWR15XCR
• 115-volt (103.5 minimum to 126.5 maximum)
• 15-amp time-delay grounded fuse or circuit breaker
• Use on single outlet circuit only.
For model HWE18VCR, HWR18VCR
• 230/208 volt (187 min. to 253 max.)
• 15-amp time-delay fuse or circuit breaker
• Use on single outlet circuit only.
For model HWE24VCR, HWR24VCR
• 230/208 volt (187 minimum to 253 maximum)
• 20-amp time-delay grounded fuse or circuit breaker
• Use on single outlet circuit only.
REQUIRED GROUNDING METHOD
This air conditioner must be grounded. This air conditioner is equipped with a power
supply cord that has a 3 prong grounding plug. The power supply cord must be plugged
into a mating, grounded 3 prong outlet, and grounded in accordance with all local codes and
ordinances. If a mating outlet is not available, it is the customer's responsibility to contact a
qualified electrician and ensure that a properly grounded 3 prong
outlet is installed.
POWER SUPPLY CORD
NOTE: Your air conditioner's plug may differ slightly in appearance
from the one shown.
A. Reset button
B. Test button
This room air conditioner is equipped with an a leakage current detection interrupter ( LCDI)
power supply cord required by UL. This power supply cord contains a current detection device.
If the power supply cord is crushed, this device will detect current leakage and power will be
disconnected from the air conditioner. If this power supply cord is damaged, it cannot be
repaired and must be replaced with a cord from the product manufacturer. If the power supply
cord is damaged call Haier Customer Service: 1-877-337-3639.
PAGE 8
(See Fig.2)
(See Fig.2)
(See Fig.3)
INSTALLATION REQUIREMENTS
Fig. 2
HWR15XCR
HWE15XCR
HWR18VCR
HWE18VCR
115V
15 Amp
HWR24VCR
HWE24VCR
115V
230V
15 Amp
15 Amp
A
Fig. 3
B
115V
230V
15 Amp
15 Amp
230V
230V
15 Amp
20 Amp
230V
20 Amp