Maintenance
Shut off water supply
Inspect and clean all components and replace if necessary.
I. Battery
Batteries which are almost discharged are indicated
by a flashing indicator lamp.
1. Remove screw (G) and remove fitting housing (E) from wall,
see fold-out page II, Fig. [10].
2. Remove battery housing (D) and disconnect plug-in
connection.
3. Remove lid (D1) of battery housing (D), as shown
in Fig. [10].
4. Remove battery (D2) and replace.
Assemble in reverse order.
II. Solenoid valve
1. Remove screw (G) and remove fitting housing (E) from wall,
see fold-out page II, Fig. [11].
2. Disconnect plug-in connection between electronics and
solenoid valve (B).
3. Remove solenoid valve housing (A) with solenoid valve (B)
and replace.
Assemble in reverse order.

Fault/ Cause/ Remedy

Fault
Cause
Water not flowing
• Water supply interrupted
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector of solenoid valve
without contact
• Battery discharged
• Battery plug-in connector without contact
• Hands not in reception range
• Cleaning mode activated
Water flowing
• Solenoid valve defective
continuously
• Thermal disinfection activated
Undesired water flow
• Sensor system detection zone set too
high for local conditions
• Automatic flushing activated
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Main shut-off valve not fully open
• Water supply restricted
III. Filter
1. Remove screw (G) and remove fitting housing (E)
from wall, see fold-out page II, Fig. [11].
2. Disconnect plug-in connection between electronics
and solenoid valve (B).
3. Remove solenoid valve (B) and clean filter (B1),
see Fig. [12].
Assemble in reverse order.
Replacement parts, see fold-out page I.
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.

Disposal note

Dispose of batteries in accordance with national
regulations.
Remedy
- Main shut-off valve open
- Clean filter
- Replace solenoid valve
- Attach plug-in connector
- Replace battery
- Attach plug-in connector
- Hold hands directly under the spout
- Deactivate cleaning mode or wait 3 minutes
- Replace solenoid valve
- Wait 3.5 or 11 minutes
- Reduce range using remote control
(special accessory, Prod. No.: 36 206)
- Wait 1 - 10 minutes
- Clean or replace mousseur
- Clean filter
- Fully open main shut-off valve
- Check supply lines