Make sure that moving parts do not move unexpectedly.
Used or leaked fluids, and any other products consumed during the activities, must be collected and
disposed of in a environmentally responsible way.
3
Description
3.1
Product identification (Fig. 1)
1. Push-button "+" (lifting/inflating)
2. Push-button "-" (lowering/deflating)
3. Adapter inlet air
4. Inlet air couplings
5. Outlet air couplings
6. Pressure gauge
7. Guard ring
8. RFID label
3.2
Dimensions (Fig. 2)
/i
Model
Part no.
SCV 10 U
350.582.042
DCV 10 U
350.582.034
3.3

Technical specifications

/i
Model
Standards
Country of manufacture
Temperature range
Max. pressure
3.4
RFID
This Holmatro product is equipment with a Radio Frequency IDentification (RFID) tag. This proven
technology does not interfere with existing communication systems. The RFID tag in this product is
programmed with the equipment's details and can be used in combination with a free web based asset
management system from Holmatro. For more information about RFID and Holmatro equipment please
visit www.holmatro.com/rescue where you can find all the details.
4

Preparation for first use

Check the equipment for completeness and damage. Do not use the equipment if it is damaged;
in that case contact the Holmatro dealer.
Before use, first read the operating instructions of this tool and for the tool to be controlled.
Check the hose kit for damage and ensure correct fitting of couplings, etc.
Check the compressed air source for an operating pressure of 8 bar.
SCV/DCV 10 U
Width
A (mm)
104
214
Between -20 ºC and +55 ºC
916.279.030_002
Length
B (mm)
221
SCV / DCV 10U
EN 13731
The Netherlands
8 bar
EN
Height
C (mm)
121
15