Bath inlet
Memory button 1
Memory button 2
- In the delivery condition, all programme buttons appear on
the operating panel.
- In setting mode under Ports, a maximum of three different
programme buttons can be allocated to the outlets. The
solenoid valve of the unused outlet can be switched off.
- The memory button functions can be adapted or changed
in setting mode under Preset.
- The bars on the display illustrate the chronological
sequence of the relevant programme.

Setting mode

Setting mode is activated as follows:
1. Switch on the fitting via the
temperature to 33 °C using the
2. Press the buttons in a clockwise sequence:
3. When, after pressing for the third time, the GROHE logo
appears, confirm with the button.
Setting mode is now activated and Menu appears in the
display.
This is confirmed using the button on the operating panel.
Adjustment is made using the
mode by pressing the
button.
The following settings can be changed using the operating
panel:
Clock (set time)
13:26
13:26
°C / °F (temperature unit conversion)
°C
°F
Limit (change temperature safety stop)
39 °C
Demo (activation of demonstration programme)
Off
On
The programme starts 60 s after a button is last touched.
Ports (assignment of connections)
1 2 3
1 2 3
1 2 3
If the water routes are transposed, assignment of the
programme buttons can be adapted accordingly.
Touching the same programme button twice, switches
off the solenoid valve of the relevant connection.
Reset (reset factory settings)
Factory set? No
Factory set? Yes
Saver (time until screensaver appears)
5 sec
button and set the
button.
buttons. End setting
Versions (show relevant software version)
000 (operating panel)
000 (function unit)
Visual (set colour of the temperature arrows)
Red/Blue
Orange
Standby (select screensaver)
Off
GROHE
13:26
Contrast (set background contrast)
12
Preset (program operating panel)
Only the programme buttons defined under Ports
in the section Setting mode appear.
Section 1
Ports 1 2 3
Time
Temp
Volume
Section 2
. . . .
. . . .
Section 7
Section 1
. . . .
. . . .
. . . .
Resume (time for pause mode)
60 sec
Protect (time for safety shut-off)
30 min
Max (switching 43 °C stop on/off)
On
Off
The display flashes if 43 °C is exceeded.
Optimal (define start temperature and volume)
First make settings in the Calibrate menu.
38 °C
Calibrate (adjust function unit)
38 °C | 0
Volume Min | 1
Volume Max | 30
Therm. disinfection
Start
Risk of scalding
Leave the wet zone immediately after the start
of thermal disinfection.
- Thermal disinfection starts after 10 s. The bars on the
display illustrate the remaining time.
- Thermal disinfection can be stopped at any time by pressing
any button.
- During thermal disinfection, all assigned outlets are flushed
for 3 minutes, one after the other.
- If the flow temperature of 70 °C is not reached, X Therm.
disinfection appears in the display.
Maintenance
Inspect and clean all parts, replace as necessary and lubricate
with special grease.
Non-return valve (08 565), see fold-out page I.
Assemble in reverse order.
Replacement parts, see fold-out page I (* = special accessory).
0
38.0
1