Malfunction
• Buffer solution defective
Calibration
• The sensor is dirty or defective
impossible
• The sensor is worn
(error message)
or
Redox sensor
reliability < 25%
Slow Redox sensor
Redox sensor is electrostatically
response
charged
The free chlorine
• Water balance is incorrect (High
level is too low
pH, etc.)
(murky water)
• The Redox set point is too low
• The daily filtering time is too
short
The free chlorine
• The water balance is incorrect
level is too high
(Low pH, etc.)
• The Redox set point is too high

6. Registering the product

Register your product on our website:
-
be the first to be informed of new Zodiac products and special offers,
-
help us to constantly improve our product quality.
Australia – New Zealand
Europe, South Africa & Rest of the World
H0435000.A - EN - 2013-11
Possible causes
• Check that the solution used is 465mV
• Use new buffer solution
• Begin calibration again
• Check the condition of the sensor tip
• Check the porosity of the sensor
• Clean the sensor by leaving its extremity in a 10% solution
• Replace the sensor
The sensor must not be wiped using a cloth or paper, shake
it gently
• Check and correct the water balance parameters (see
• Use the «Boost» mode
• Make sure the set point is above 650mV
• The daily filtering time must be at least 12 hours per day
• Check and correct the water balance parameters (see
• Make sure the set point is not too high
• Power off the appliance
Solutions
of hydrochloric acid
§2.1.1).
during the season
§2.1.1)