G
B
R=2,2K
AUTOTEST EDGE
ACCESSORY SUPPLY
POINT B - SETTINGS
DIP 1 (ON) MOTOR ROTATION DIRECTION CHECK (See Point C)
DIP 2 (ON) PROGRAMMING (See Point D)
DIP 1-2 STORAGE/DELETION OF RADIO CODES FOR COMPLETE OPENING
(DIP 1 ON followed by DIP 2 ON) (POINT G) ONLY FOR CRX MODELS
DIP 1-3 STORAGE/DELETION OF RADIO CODES FOR PEDESTRIAN OPENING
(DIP 1 ON followed by DIP 3 ON) (POINT H) ONLY FOR CRX MODELS
DIP 2-1 PROGRAMMING OF THE PEDESTRIAN OPENING (See Point F)
DIP 3
ON - Automatic Closing ENABLED
OFF - Automatic Closing DISABLED
DIP 4
ON - Photocells active only in closing
OFF - Photocells always active
DIP 5
ON - blinker pre-flashing
OFF - blinker normal-flashing
DIP 6
OFF - STEP BY STEP
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
ON - AUTOMATIC
Single pulse contact (K BUTT)
Pedestrian button (PED BUTT)
Radio Receiver command
DIP 7
ON - low speed in approaching ENABLED
OFF - low speed in approaching DISABLED
DIP 8
ON - electric lock command ENABLED
OFF - electric lock command DISABLED
DIP 9
ON - Hammering on complete close position to ease Manual Release
- Hammering before opening to ease electric lock unlocking
OFF - no impulse
DIP 10 ON - Extra thrust when reached closing position to make sure that the mechanical bolt is
fixed into the ground
OFF no impulse
DIP 11 ON - black out function ENABLED
OFF - black out function DISABLED
DIP 12 ON - close command after the transit through the photocell ENABLED
OFF - close command after the transit through the photocell DISABLED
DIP 13 ON - safety strip self-test ENABLED
OFF - safety strip self-test DISABLED
DIP 14 OFF
DIP 15 OFF
DIP 16 OFF
JP 17 OPEN JUMPER 1 motor (M1) - 1 leaf
CLOSE JUMPER 2 motors (M1 and M2) - 2 leaves
AERIAL
COAX
SIGNAL
BUZZER
+
-
24 Vdc for
+
-
24 Vdc for
+
-
PHOTOCELL
EDGE
K BUTTON
+
PED. BUTTON
COM
ELECTRIC
LOCK
MOTOR 2
MOTOR 1
POWER SUPPLY
JP1 => Pay attention that the jumper is inserted!
JP2 => Pay attention that the jumper is inserted!
JP3 => Pay attention that the jumper is inserted!
TORQUE TR1 Electronic regulator for motor torque
Adjustment of motor torque is carried out using the TORQUE Trimmer which varies the output voltage
to the head/s of the motor/s (turn clockwise to increase torque).
This torque control is activated after 2 seconds form any manoeuvre begging, whereas the motor is
turned on at full power to guarantee the starting at the manoeuvre begging.
PAY ATTENTION: IF THE TORQUE TRIMMER SETTING IS CHANGED, IT IS PREFERABLE TO
REPEAT THE TIME PROGRAMMING.
LOW SPEED TR2 Electronic regulator for low speed on approach
Adjustment of low speed is carried out using the LOW SPEED Trimmer which varies the output voltage
to the head/s of the motor/s (turn clockwise to increase speed). Adjustment is carried out to establish
the correct speed at the completion of opening and closing, depending on the structure of the gate,
or if there is any light friction that could compromise the correct working of the system. The low
speed is activated (DIP7 OFF) when the gate leaf is 0.50-0.60 meters away from the complete close
or open position.
ATTENTION: WHEN USING HYDRAULIC OPERATORS. When using the hydraulic operators the
deceleration phase may not operate correctly; in that case it is advisable to disable the
feature of the deceleration by putting DIP 7 in the OFF mode
LED WARNING
DL1 - programming activated (red)
DL2 - radio code programming (green) (only for CRX)
DL3 - gate opening M2 (green)
DL4 - gate closing M2 (red)
DL5 - gate opening M1 (green)
DL6 - gate closing M1 (red)
DL7 - photocell contact (NC) (red)
DL8 - safety strip contact (NC) (red)
FUSES
F1 T315mA
Accessories protection fuse
F2 5A
Motor protection fuse
POINT C - MOTOR ROTATION DIRECTION CHECK
1 - Unlock the operators with the Manual Release - swing open the leaves about halfway and lock
again the operators.
2 - Turn DIP1 to ON position The red LED DL1 starts blinking.
3 - Press the PROG button and hold it - When GREEN LEDS DL3 and DL5 are on, the gate leaves are
opening (with a phase shift of 2 seconds). Check the leaves swinging and the opening mechanical
BLINKER
CAPACITOR M2
CAPACITOR M1