Noted defect
No digital display
ignition
Ignition of fan is
OK, but heat pump
don't works
Heat pump works
correctly but stop
few minutes after
starting
Heat pump works
but pool water
temperature don't
increase anymore
(or too slowly)
Probable cause
Relay is not connected
to "1" and "5"
Defrost is working
Problem of gas charge
This heat pump don't fit
well to your pool
By-pass needs setting
No cover
Checking
Verify connections
-
Check if pressure
controller indicates
between 5 and 10 bars
when heat pump is
stopped
Check with Polytropic
software
www.polytropic.fr
"aquavariation" menu
Check by-pass setting
Please see if there is cover
under swimming pool
34
Answer
Install relay
Till ambient
temperature is OK,
heat pump will start
working
Contact your seller
Contact your seller
Please see setting
chapter of this
handbook
Install a solar cover
during the heating