double click the START button to toggle between the
two audible alarm options. The instrument will store
the current alarm setting when turned OFF, thus
becoming the operation alarm the next time the
instrument is powered up.
TURNING THE INSTRUMENT OFF
At any time during operation, press and hold down
the START button until the LED display turns OFF.
This indicates that the unit has been shut down.

SENSOR STATUS INDICATOR

If the sensor is damaged, every other one of the
tachometer LED's will light up visibly notifying the
user of the problem, and then the instrument turns
itself OFF.

LOW BATTERY INDICATOR

When the batteries reach approximately 10% of
capacity, the rightmost tachometer LED will stay lit
above the LO BAT legend.
CONTROL
Single momentary push-button operates all functions
of the unit:
• With the instrument OFF, click the START
button once to turn it ON. The instrument is
automatically calibrated and ready to search
for leaks.
• With the instrument ON, holding the button down
for 3 seconds turns the instrument OFF. Audible
alarm setting is remembered.
• With the instrument ON, double clicking the
button changes the audible alarm from high to
low intensity and vice versa.
• With the instrument ON, clicking the button once
resets the instrument to maximum sensitivity and
nulls out any ambient contamination.
SEARCHING FOR LEAKS
The LS3000 is fully automatic and need only be
turned on to begin a leak search. All necessary
sensitivity and calibration settings are automatically
selected by the unit's advanced POWERSHIFT™
software providing optimal leak searching
performance under any conditions.
SAE J1628 Recommended Leak Search Procedure
Note: On automotive A/C systems, test with the
engine not in operation.
1. The air conditioning or refrigeration system should
be charged with sufficient refrigerant to have a
gauge pressure of at least 50 psig/340kPa/3.4 BAR
when not in operation. At temperatures below 59°F/
15°C, leaks may not be measurable, since this
pressure may not be reached.
2. Take care not to contaminate the detector probe
tip if the part being tested is contaminated. If the
part is particularly dirty, or condensate (moisture)
2