1 INFORMATION ON INSTALLATION.
Installation and maintenance must be performed
by authorised and qualified technicians; they have
to know our products and be acquainted with
European standards for installation of industrial
laundry equipment. In absence of legislation, the
installation
must
conform
standards.
The dryer must be installed on a solid floor
capable of supporting its weight (the machine
weight is indicated on the silver-plated label on
the machine back) The dryer is equipped with four
feet to be screwed to the relative four threaded
holes on the base. The machine must be installed
perfectly in level.
To
ease
installation
recommend to leave some space around the
machine
(see pict. 4 page 33).
The machine must be installed into an aired room:
the dryer must be vented to the outdoors.
The dryer must be installed in an aired room; it is
forbidden to install the dryer in presence of
machines which work with perchlorate. The
combustion produces chloridric acid fumes which
may damage linen and machines.
If propane heated machines are installed in
basements it is necessary to install adequate
forced ventilation devices.
Gas heated professional equipment must be
considered gas machines without any regard to
their dimensions.
Gas heated machines which need the air of the
room as supporter of combustion must be
installed in rooms where there is an adequate air
circulation with the outdoors.
If the room is vented mechanically, the air
circulation can be considered good when the
machine
environmental
produces no depression. This assures the regular
gas combustion and the total exhaust evacuation.
The air circulation testing must be performed
according to measures in force.
The room opening for ventilation may be equipped
only with controlled locking devices which must
remain opened during combustion.
To prevent fire hazard or explosions do not stand
near the machine with explosive or inflammable
products.
It is forbidden to put anything in the machine other
than the items to be dried. Do not load the
machine with fabrics contaminated by dangerous
substances such as explosives, inflammables,
applicable
CE
and
maintenance
we
nominal
overheating
etc. Make sure they are rinsed or aired before
drying.
In accordance to legislation on machine noisiness
dryers' noisiness is inferior to 80 dB
Before positioning and wiring the dryer, the
installer has to check whether gas, steam and
power supplies conform to machine specifications.
These data are on the inner part of the small door,
in the machine back (see fig. 1 pag.33).
For the machine installation the technician must
respect the following regulations:
-
Building and/or territorial regulations and fire-
prevention regulations;
-
Accident prevention measures in force;
-
CEI regulations on electric installations;
-
Gas supplier (either body or company)
regulations;
-
Regulations of the power supply company;
-
Other local regulations.
Make sure to take off all residual packaging (card
board and cellophane film) form the dryer panels.
In case of mal-functioning or failure, turn off the
machine immediately!
If the machine has to be bolted to the ground, the
installer must ask for adaptors (see pict. 6 page
34).
1.1 ELECTRIC CONNECTION.
All the dryers are equipped with a terminal board
on the back panel; all the electric connections
must be made on this board a duly dimensioned
multipole feed cable (see table 2, 3 and 4 pag. 5
and 6 ) should be inserted in the cable holder
located in the machine rear (see fig.2 pag.34 ref.
FL) and connected to the following terminals:
-
three grey terminals (phases: L
-
one blue terminal (neutre: N);
-
one yellow-green terminal (earth).
The earth wire must be longer than the other
wires because it must disconnect after the phases
wires in case of tensile stress or damage of the
cable holder.
With regard to the external electric installation,
each machine should be connected to a single
magneto-thermal switch and power cut-off safety
device.
The multipole feed switch must be placed near the
machine and it must be easily accessible to
installer.
Each machine must be connected to ground: the
manufacturer is not responsible for any
consequence arising from the neglecting of
safety regulations.
Once connected the machine, open the lint door
and control whether the fan turns clockwise:
should it rotate counter-clockwise disconnect the
02/12/04