Electrical Supply - Merrychef Mealstream EC401 Nformación Importante

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ELECTRICAL SUPPLY

WARNING
This appliance must be earthed. Failure to do so may result in electric shock and death.
Mealstream EC40EE5, RD40 (3A) UK models
The electricity supply lead is located at the rear of the oven.
All UK models are supplied with a fitted and approved 13
amp moulded plug. We strongly recommend that this plug is
never removed. However certain establishments may require
a different plug to be fitted. In this case, the following wiring
instructions should be observed
New plugs should only be fitted by a qualified electrician.
The power outlet used must be individually fused at 3 Amps.
It is essential that the socket is properly installed and earthed.
It should be fed from a circuit which is suitable for high power
electrical appliances and it is important that this circuit is not
overloaded.
Warning: Never use extension leads or adaptors.
Mealstream EC40XX5 EC40XE5, RD40XE, EC403XE, EC403XX5 (30A)
WARNING
The Mealstream EC40 & RD40 ( 30A ) must be connected to a separate electrical supply rated at 30 Amps by
a qualified and approved electrician. A suitable 30 amp rated isolating switch with a 3mm contact gap on both
poles should be fitted for each oven installed.
Establishments with standard ( Type 'B' ) circuit breakers are sensitive to 'surges' which occur on switching on
freezers, refridgerators and other catering equipment, including microwave ovens. Because of this, we strongly
recommend that a separate Type 'C' circuit breaker ( designed specifically for this type of equipment ) must be
fitted. An individual, suitably rated circuit breaker should be fitted for each oven installed.
EC40XX5 & EC403XX5 models only
This equipment complies with EN6000-3- when connected to a mains supply having a maximum impedance
(Z
) of 0.35ohms.
max
The user should determine in consultation with the supply authority, if necessary, that the equipment is connected
only to a supply of Z
max
SINGLE PHASE
UK models are fitted with a Blue 32Amp Plug to
BS EN 60309.
The Circuit Breaker should be rated at 45A (TypeC).
TWIN PHASE
The Mealstream 40 oven Twin Phase models should be
connected as shown.
The Circuit Breaker should be rated at 6amps/ phase
(TypeC).
If you are in any doubt about your electrical
supply, seek the advice of a qualified electrician
or less.
SINGLE PHASE
TWIN PHASE
4
Tabla de contenido
loading

Este manual también es adecuado para:

Mealstream rd401Mealstream ec403

Tabla de contenido