Whirlpool WFE550S0HZ Instrucciones De Instalación página 11

Estufas eléctricas autosoportables de 30" (76,0 cm)
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1. Part of metal ground strap must be cut out and removed.
A. Metal ground strap
B. Discard
C. Ground-link screw
2. Use a Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground link under the screw.
3. Pull the wires through the strain relief on bottom of range.
Allow enough slack to easily attach wiring to the terminal
block.
A
D
E
F
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
D. Bare (green)
ground wire
4. Attach terminal lugs to line 1 (black), neutral (white), and line
2 (red) wires. Loosen (do not remove) the setscrew on the
front of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten setscrew to torque
as shown in the following Bare Wire Torque Specifications
chart.
C
D
A. Terminal lug
B. Setscrew
C. Line 2 (red) wire
D. Neutral (white) wire
E. Line 1 (black) wire
A
B
C
B
C
G
E. Line 2 (red) wire
F. Neutral (white) wire
G. Line 1 (black) wire
A
B
E
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3
N-m).
W
i
e r
A
w
g
8 gauge copper
6 gauge aluminum
5. Use a hex or Phillips screwdriver to connect the bare (green)
ground wire to the range with the ground-link screw and
ground-link section. The ground wire must be attached first
and must not contact any other terminal.
6. Use ³⁄
" (1.0 cm) nut driver to connect the neutral (white) wire
8
to the center terminal block post with one of the 10–32 hex
nuts.
A
B
C
A. 10–32 hex nut
B. Line 2 (red)
C. Bare (green) ground wire
D. Ground-link screw
7. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
3-wire connection: Direct Wire
Use this method only if local codes permit connecting ground
conductor to neutral supply wire.
1. Pull the wires through the conduit on cord/conduit plate on
bottom of range. Allow enough slack to easily attach the
wiring to the terminal block.
A
D
E
A. Terminal block
B. Ground-link screw
C. Cord/conduit plate
T
o
q r
u
e
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
G
F
D
E
E. Neutral (white) wire
F. Line 1 (black)
G. Terminal lug
B
C
F
D. Line 2 (red) wire
E. Bare (green) ground wire
F. Line 1 (black) wire
11
Tabla de contenido
loading

Este manual también es adecuado para:

Wfe505w0hw

Tabla de contenido