OPL-ADVANTAGE – OPL system
3.2.5
Selecting delay time units:
Pump delay times can be set in one second increments for 0 - 255 seconds, or one minute increments for 0 – 99
minutes. Determine the longest delay time required for the system and select the appropriate delay time units.
1) Enter access code (see par. 3.2.1) ;
2) Select PUMP "3" and FORMULA "A";
3) Press
to select 001(seconds) or 060(minutes) on the display:
4) Press ENTER to confirm.
5) Press RESET.
3.2.6
Programming pump delay times:
1) Enter access code (see par. 3.2.1) ;
2) Ensure that the delay time LED is flashing. If not, press MODE to select delay time.
3) The 3-digit display shows 0 0 0 if delay units are seconds or - 0 0 if delay units are minutes;
4) Use the SELECT buttons to choose desired pump and formula.
5) Use
to set the delay time;
6) Press ENTER to confirm.
7) Press RESET
3.2.7
Programming flush:
If a Flush Manifold is being used, you need to program the time. To perform the f
1) Enter access code (see par. 3.2.1) ;
2) Dispense an ounce of chemical into the manifold. (Use a colored product)
3) Choose pump F and the formula number with the pump and formula SELECT buttons.
4) The pump time LED should be flashing. If not press MODE to choose pump time.
5) Press CAL. The flush solenoid will open and the 3-digit display will start counting the flush time.
6) Once the product is cleared from the line, press CAL again to stop the flush. The display will stop
counting and the display will indicate the time needed to flush the line.
7) Press ENTER and the display will flash and the flush time is set.
8) Repeat these steps for each formula - - - -
9) You can manually program the flush time by selecting pump F and the desired formula. Set the flush
time with the
OPL-ADVANTAGE
Seconds
Seconds
OR
KEYS.
code 0000136607
Minutes
Minutes
ollowing procedure:
rev. 1.6 EN
10