OPL-ADVANTAGE – OPL system
3.2
Programming
NOTE: Read thoroughly before programming
• To program, prime, or clear memory enter the access code.
• Pump "F" is used to program the flush manifold.
• Formula "A" is used for storing the access code, setting signal lock-out time, system lockout time, pump 7
& 8 enable/disable, delay units, drain mode, and pump level enable/disable.
• Formula "r" is displayed for relay mode.
• A "load count pump" must be set for proper system operation.
• Pumps 1 - 6 accepts two different injection amounts (Level 1 and Level 2) during a formula.
Pump numbers and their corresponding second level are as follows:
Pump/Second Level
E
VERY TIME YOU CHANGE A PARAMETER PRESS
3.2.1
Access code
To enter the system without an access code:
1) Press
key and then ENTER;
To enter the system with an access code:
1) Select the correct code with
2) The 3-digit display will blink for 3 seconds:
3) The pump time led will begin blinking;
4) The number 1 will appear in the PUMP SELECT and FORMULA SELECT displays;
3.2.2
Clearing the memory
1) Enter access code (see par.3.2.1);
2) Hold simultaneously - MODE and FORMULA SELECT for 3 seconds;
3) All the led will be off and the 3-digit display appears:
CLr displays for 10 seconds and then the system returns to normal operation.
3.2.3
Change access code
1) Enter access code (see par. 3.2.1) ;
2) Select PUMP "1" and FORMULA "A";
3) Select a new code with
4) The 3-digit display will blink for 3 seconds to confirm the change.
3.2.4
Programming Pump Run Times/Priming
Enter access code (see par. 3.2.1) ;
1)
2) The pump time LED should be flashing. If the delay time LED is flashing, scroll to pump time with the
MODE key.
3) Using the PUMP SELECT button choose the pump. Then do one of the following:
4) If pump run times haven't been programmed, press "CAL" to manually start and stop the pump.
Press ENTER to set the time after each pump is calibrated. (Pump run times can also be set by
scrolling the arrow keys up or down to the desired run time in seconds and then pressing ENTER).
5) If pump run times have been programmed, press "PRIME" to activate the set run time for the pump.
This will also confirm the accuracy of the programmed run time (volume). Press "RESET" to stop the
pumps during the prime function.
Example: If in formula 1 we have programmed a time for pump 1 of 20 seconds, with the
PRIME key you'll have a priming maximum of 20 seconds.
OPL-ADVANTAGE
1/A; 2/B; 3/C; 4/D; 5/E; 6/0
keys (default is 000) and after press ENTER;
and then press ENTER;
code 0000136607
RESET
.
KEY
rev. 1.6 EN