Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1. POWER
When you activate the board the red LED
switches on steadily for about 3 seconds.
After about 1 second, the green LED will flash a
number of times equal to the review.
When the red LED switches off, the green LED
switches on steadily indicating that the switch on
procedure of the card is completed and now it is
ready for operation.

2. OPERATING LOGIC

The control unit has 4 operating logic:
1. Automatic: opening and closing are automatic.
2. Dead-man in closing: opening is automatic while closing is dead-man.
3. Start-Stop Multi-residential: opening and closing via dedicated controls (terminals 7-8 and 8-9 or
UP/DOWN buttons on the integrated keyboar) are in automatic logic. The Start-Stop (terminals 6-8)
instead always controls the opening until the door is fully open. When the door is fully open the
Start-Stop controls closing.
4. Dead-man in opening and closing.
The logic of operation is selected using DIP 1 and 2 according to the following table:
OPERATING LOGIC
Automatic
Dead-man in closing / Automatic in opening
Start-Stop Multi-residential
Dead-man in opening and closing
2.1 WIRELESS OPERATING MODE
This operation mode requires:
1. Selection of the operating mode
2. Connection of a radio receiver QCRS1:
2.1.1 WIRELESS OPERATING MODE "AUTOMATIC"
- DIP1 and DIP2 in OFF
- [1 - 2] > Power supply
- [6 - 8] > Signal
RED
LED
DIP 1 DIP 2
OFF
OFF
OFF
ON
ON
OFF
ON
ON
24Vac
SAF
COM
1 2 3 4 5 6 7 8 9 10
24Vca
P. Supply
GREEN
LED
STOP
SS DW
COM
UP
signal
GRD
13