Excluding The Automatic Closure; Selection Of The Working Logic; Dead Man Closure; Safety Beam Logic - GAPOSA QCzero Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

QCzero QCzeroP
28
EN

3.7.3 EXCLUDING THE AUTOMATIC CLOSURE

This procedure excludes the automatic closure by erasing the pause time. Once excluded, it can be reactivated with the
programming of the pause time.
OPERATIONS
1. Place the control unit's dip 8, 9, 10 in ON position.
2. Place in OFF position only the dip 9 and 10. The dip 8 remains in ON.
3. When the TEST led starts flashing it is time to place in
OFF the dip 8 as well. The erasing procedure is finished

4 SELECTION OF THE WORKING LOGIC

The control unit can deal with two working logic for the Start/Stop (SS) control: STEP- STEP or COMMON.
LOGIC DESCRIPTION
STEP-STEP: The SS control performs at every activation the following operations:
OPEN > STOP > CLOSE > STOP in sequence. During a pause a SS control excludes the
automatic closure, the following control closes the door.
COMMON: The SS control performs always an opening, except in the case of an
already and completely open door. In this case it performs a closure.

4.1 DEAD MAN CLOSURE

It is possible to activate the "dead man" function for the control CLOSE.
LOGIC DESCRIPTION
DEAD MAN closing control: with this logic the CLOSE input works always in the dead
man way (also through radio transmitter, provided that it is programmed for a three
buttons control UP-STOP-DOWN. See par. 3.4 pag. 25). ATTENTION: the SS and OPEN
controls remain with the impulse logic! The automatic re-closure is excluded.

4.2 SAFETY BEAM LOGIC

It is possible to choose two working modalities for the safety beam connected to the terminals 8 and 9.
LOGIC DESCRIPTION
FUNCTION DURING CLOSURE (place the dip 3 in OFF position): while closing
the safety beam's activity inverts the movement of the opening door.
FUNCTION DURING CLOSURE AND OPENING (place the dip 3 in ON position): while closing the safety beam's
activity inverts the movement of the door. while opening the safety beam's activity stops
the movement of the door.
Control unit with integrated receiver
ON
ON
1 2 3 4 5 6 7 8 9 10
TEST
FLASH
ON
1 2 3 4 5 6 7 8 9 10
ON
ON
1 2 3 4 5 6 7 8 9 10
ON
ON
1 2 3 4 5 6 7 8 9 10
ON
ON
TEST
OFF
Tabla de contenido
loading

Este manual también es adecuado para:

Qczerop

Tabla de contenido