2.1.2 WIRELESS OPERATING MODE "DEAD-MAN IN CLOSING"
- DIP1 in OFF / DIP2 in ON
- [1 - 2] > Power supply
- [7 - 8 - 9] > Signal.
2.1.3 WIRELESS OPERATING MODE "DEAD-MAN IN OPENING AND CLOSING"
- DIP1 and DIP2 in ON
- [1 - 2] > Power supply
- [7 - 8 - 9] > Signal
3. SAFETY
The safety of the board are managed via DIP 3 and 4:
DIP 3 SAFETY LOGIC
When an obstacle is detected during the way down the movement is reversed until the opening
OFF
limit switch; It has no effect on the way up.
When an obstacle is detected during the way down the opening movement is inverted for 2
ON
seconds and then it stops. When an obstacle is detected during the way up the movement is
immediately stopped.
DIP 4 TYPE OF SAFETY SELECTION
OFF
Security input for normally closed contact.
Security input for optoelectronic bar with digital signal. To be connected as follows: Mass in
ON
terminal 10, + 12V DC in terminal 4, digital signal in terminal 3.
4. OPTOELECTRONIC BAR +
PHOTOCELL
If you wish to simultaneously connect
the optoelectronic bar QCSE and the
photocell, the latter must be connected
in series to the digital signal of the bar as
shown (DIP 4 in ON).
14
24Vac
1 2 3 4 5 6 7 8 9 10
24Vca
P. Supply
Power supply
24Vac
SAF
COM
STOP
SS DW
Photocell (contact NC)
COM
UP
GRD
signal
GRD - White
+12Vcc - Brown
SIGNAL - Green