Troubleshooting; Environmental Protection - Kress Robotik MISSIONNANO KR100 Manual Del Propietário

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51

Troubleshooting

If your MissionNANO
TM
contact your dealer.
Symptom
The LED light on the charging
base does not turn on.
Green light flashing on the
charging base.
Your MissionNANO
is inside
TM
its territory and the boundary
wire is connected. The error
indication light flashes red.
MissionNANO
cannot
TM
correctly dock with the
Charging base.
MissionNANO
runs
TM
outside the boundary wire.
MissionNANO
does not mow
TM
an area within a boundary wire
zone. MissionNANO
TM
or rotates erratically near the
boundary wire.
MissionNANO
exits the
TM
boundary wire due to high
speed when going down a hill.

Environmental protection

Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or retailer for recycling advice.
does not work correctly, follow the trouble shooting guide below. If the fault persists,
There is no power.
The boundary wire isn't
connected.
The boundary wire ends are
clamped incorrectly.
Environmental influences.
Poor connection caused by
debris on the charging strip.
The boundary wire of another
MissionNANO
branded robotic mower is
positioned too closely.
The boundary wire has been
installed with acute angles.
In wet conditions, the boundary
wire electric signal may leak
where wire has been joined or
reverses
repaired.
There is boundary wire electric
signal leakage due to broken
insulation.
The cutting area is larger than
the allowable cutting area for
MissionNANO
The boundary wire is placed on
a slope steeper than 17% (10°).
Cause
Check the charging base is connected
properly to the charger and the charger
is connected to a suitable power supply.
Check that the boundary wire has been
connected correctly to the charging base.
Check there are no breaks in the
boundary wire,especially in the wire ends.
Reverse the boundary wire ends.
Restart MissionNANO
Clean the contact pins located on the
charging base and the charging strip on
MissionNANO
Ensure your MissionNANO
or another
TM
wire has at least 1m of spacing between
the neighboring boundary wire.
Check the boundary wire to ensure the
angles are smooth.
Check boundary wire joints. Insulate to
provide a fully waterproof connection.
Repair damaged boundary wire
insulation with insulation tape.
Decrease the cutting area.
.
TM
Reposition the boundary wire away from
slopes that are steeper than 17% (10°).
Action
.
TM
using a cloth.
TM
boundary
TM
13
EN
Tabla de contenido
loading

Tabla de contenido