Fein Slugger JMU 137 QW Manual Del Usuario página 5

Ocultar thumbs Ver también para Slugger JMU 137 QW:
Idiomas disponibles

Idiomas disponibles

OBJ_BUCH-0000000355-002.book Page 5 Tuesday, March 12, 2019 4:36 PM
Safety instructions.
When performing drilling that requires the
use of a fluid, route the fluid away from the
operator's work area or use a collection sys-
tem. Such precautionary measures keep the
operator's work area dry and reduce the risk
of electrical shock.
Operate the power tool by the insulated grip-
ping surfaces, when performing an operation
where the cutting accessory may contact hid-
den wiring or its own cord. Contact of a cut-
ting accessory with a "live" wire may make
exposed metal parts of the power tool "live"
and could give the operator an electric shock.
Wear hearing protection when drilling. Expo-
sure to noise can cause hearing loss.
When the application tool jams, stop applying
pressure and switch the power tool off. Check
the cause of the jam and apply corrective
action to eliminate the cause of the jamming
application tool.
When restarting a core drill jammed in the
workpiece, check that the application tool
rotates freely before starting. If the applica-
tion tool is jammed, it may not start, may
overload the power tool, or may cause the
core drill to release from the workpiece.
When securing the drill stand with a vacuum
plate to the workpiece, make sure that the
surface is smooth, clean and non-porous. Do
not secure the drill stand to laminated sur-
faces such as tiles and coated composite
materials. If the surface of the workpiece is
not smooth, flat or well affixed, the vacuum
plate may pull away from the workpiece.
Ensure there is sufficient vacuum level before
and during drilling. If the vacuum level is
insufficient, the vacuum plate may become
detached from the workpiece.
Never perform overhead and wall drilling
when the machine is only fastened using the
vacuum plate. If the vacuum is lost, the vac-
uum plate will release from the workpiece.
When drilling through walls or ceilings,
ensure to protect persons and the work area
on the other side. The core bit may extend
through the hole or the core may fall out on
the other side.
Do not use this tool for overhead drilling with
fluid supply. Fluids entering the power tool
will increase the risk of electric shock.
Special safety instructions.
Have the protective cable bushing replaced
immediately when damaged. A defective pro-
tective cable bushing can lead to overheating
of the machine.
Wear protective equipment. Depending on the
application, wear face shield or safety gog-
gles. Wear hearing protection. The safety
glasses/goggles must be suitable to protect
against the particles emitted from different
operations. Continuous high exposure to
noise can lead to loss of hearing.
Do not touch the sharp edges of the core drill
bit. Danger of injury.
To avoid injuries, check the core drill bits
prior to starting the work. Use only undam-
aged core drill bits that are not deformed.
Damaged or deformed core drill bits can
cause serious injury.
Before putting into operation: Mount the chip
guard to the machine.
Always secure the machine with the sup-
plied safety strap. Especially on inclined
or uneven surfaces there is risk of unse-
cured machines tipping over.
When working overhead, beware of falling
objects, such as cores or chips.
When working overhead or on vertical sur-
faces, the coolant container must not be used.
Use Slugger Cutting Paste instead. Liquids
penetrating your electric power tool may-
cause electric shock.
Avoid touching the drilled core that is auto-
matically ejected by the pilot pin when the
working procedure is finished. Contact with
the core when it is hot, or if it falls, can cause
personal injuries.
Operate the power tool only from grounded
contact sockets that comply with the specifi-
cations. Do not use any connection cables
that are damaged; use extension cables with
a grounded contact that are checked at regu-
lar intervals. A ground conductor without
continuity can cause an electric shock.
en
5
loading

Este manual también es adecuado para:

Slugger jmu 137 mqwSlugger jmu 137-2 qwSlugger jmu 137 pqw